Epump Dip Switch Settings; Auxiliary Load Operation - Jandy ePump Pro Serie Manual De Instalación Y Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Jandy
Pro Series ePump
®
6.
Select the desired address(es) for the ePump +
SVRS(s) by setting dip switches 3 and/or 4, as
shown in Section 3.3, ePump + SVRS Dip Switch
Settings.
7.
Connect the other end of the cable to an RS-
485 connector on the AquaLink (or multiplexer
interface board), matching wire colors with
connector positions, as described in Step 3.
8.
Restore power to the ePump + SVRS and verify
the operation of the controller.
9.
Refer to the appropriate control manual to operate
the pump. ePump + SVRS Controller Owner's
manual (H0412200), AquaLink
Manual (6593), AquaLink PDA Owner's Manual
(H0572300), or AquaLink Z4 Owner's Manual
(H0386600).
3.3 ePump + SVRS Dip Switch Settings
As shown in
Figures 4 and 5,
is located at the rear of the ePump + SVRS. This dip
switch serves two (2) functions: it selects the pump
address, and it determines what type of controller will
be used with the pump.
The tables below show the dip
switch
settings.
Switch 1 Switch 2
Controller
OFF
OFF
AquaLink RS, AquaLink PDA
or AquaLink Z4
ON
ON
ePump + SVRS Controller
(JEP-R)
Switch 3 Switch 4 Pump Address
OFF
OFF
PUMP 1
ON
OFF
PUMP 2
OFF
ON
PUMP 3
ON
ON
PUMP 4
3.4
Auxiliary (Aux) Load Operation
The Jandy Pro Series ePump + SVRS is equipped with
a terminal bar that provides user access to a built-in
Auxiliary Load relay contact. This normally-open, dry
contact is activated under certain operating conditions
and is primarily intended to be used to control external
devices that require system water flow for proper
functioning, such as heaters, booster pumps, salt water
chlorinators, etc.
See Figures 6,7 and 8 for compartment's location
details. An access cover with Phillips-head screw must
be removed before proceeding.
|
+ SVRS
Installation and Operation Manual
RS Owner's
®
the 4-position dip switch
Aux Load Connection Requirements
WARNING
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or
injuries to persons, Jandy Pumps must be installed
in accordance with the National Electrical Code
(NEC
), all local electrical and safety codes, and
®
the occupational Safety and Health Act (OSHA).
Copies of the NEC may be ordered from the National
Protection Association, 470 Atlantic Ave., Boston,
MA 02210, or from your local government inspection
agency.
In Canada, Jandy Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
Note: The Auxiliary Load relay contacts are rated at
230V/11A RMS. Please ensure the requirements of the
equipment to be connected to the Auxiliary Load do not
exceed this rating.
Wiring Diagram for 230V Aux Load, Shared
Power Source
Note: In this configuration, it is important to verify
the shared power source is adequately rated
to service both the pump and the auxiliary
equipment.
1
2
F1015
TP133
TP130
/100
TP127
Earth
230V
Earth
Auxiliary
Load
Figure 6.
230V Aux Load, Shared Power Source
Wiring Diagram
ENGLISH
Page 13
®
L2 L1
F1014
L1
(Black)
Power
Source
L2
(Red)
L2
(Red)
230V