Led Light Installation; Section 3. Winterizing; Section 4. Troubleshooting; Corrective Action - Jandy TruFit HCBUB Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TruFit Bubbler | Owner's Manual
2.4

LED Light Installation

The Jandy TruFit
be fitted with a Jandy
tests have been completed and the Small Construction Cover has been
removed, you are ready to install the Jandy HydroCool Nicheless Light into
the Bubbler Housing.
1.
Feed the power cable through the housing and conduit to the power
source. Allow 18"-24" slack for service loop.
2.
Place the Light into the Bubbler and tighten into the threaded housing.
3.
See the Jandy HydroCool Nicheless light Owner's Manual for light
installation instructions.
Section 3.
Do not keep the winter water level at the level of the light. Make certain that
the water level is left at least 4" or more above or below the light depending
on the pool's other winterization needs. Consult a Local Swimming Pool
Professional for proper winterization. At NO TIME should there be water
removed from the pool without checking ground water tables.
Section 4.
Use the troubleshooting information in the following table for suggestions.
Symptom
All lights fail to illuminate
One or more lights are dim,
blinking or not working
Colored lights out of synch
Bubbler with Pressure Check Technology is designed to
TM
HydroCool Nicheless Pool Light. Once the pressure
®
Winterizing
Troubleshooting
Problem
Lights are not
receiving power
Poor connection
or improper wire
gauge
Improper voltage
supply or poor
connection to the
light
ENGLISH

Corrective Action

Check 120VAC power supply into
transformer. Check for 12VAC output at
transformer. If 120 volts was used in the
installation, damage may result and will
not be covered under warranty.
Separate each light and independently
wire 12V to the single light only. Repeat
this process on each light. If junction box
is being used, check for proper connec-
tion of light cord. Verify that the correct
wire gauge is being used between the
transformer and junction box.
Verify that proper wire connections are
being achieved for the lights that are out
of synch. Reset all the lights to white by
turning lights OFF for five (5) seconds,
then turning ON.
Page 11
Tabla de contenido
loading

Tabla de contenido