Conducting Pressure Test; Svrs Testing; Section 4. Operation; Start-Up - Jandy ePump Pro Serie Manual De Instalación Y Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Page 16
ENGLISH
3.6

Conducting Pressure Test

WARNING
When pressure testing a system with water, air
is often trapped in the system during the filling
process. This air will compress when the system is
pressurized. Should the system fail, this trapped air
can propel debris at a high speed and cause injury.
Every effort to remove trapped air must be taken,
including opening the bleed valve on the filter and
loosening the pump filter basket lid while filling the
pump.
WARNING
Trapped air in the system can cause the filter
lid to be blown off, which can result in death,
serious injury, or property damage. Be sure all
air is properly purged out of the system before
operating. DO NOT USE COMPRESSED AIR TO
PRESSURE TEST OR CHECK FOR LEAKS.
WARNING
Do not pressure test above 35 PSI. Pressure
testing must be done by a trained pool
professional. Circulation equipment that is not
tested properly might fail, which could result in
severe injury or property damage.
WARNING
When pressure testing the system with water, it is
very important to make sure that the pump filter
basket lid is completely secure.
1.
Fill the system with water, using care to eliminate
trapped air.
2.
Pressurize the system with water to no more than
35 PSI.
3.
Close the valve to trap pressurized water in the
system.
4.
Observe the system for leaks and/or pressure
decay.
5.
If there are lid leaks, repeat Steps 1-3. For
technical support, call Zodiac
at 800.822.7933.
6.
After successfully completing the test, discard the
blue pressure test o-ring.
3.7

SVRS Testing

The SVRS unit must be tested for proper operation after
installation and monthly, thereafter.
1.
Using a ball valve, butterfly valve or sliding gate
valve installed within 2 feet (0.6m) upstream from
the pump, simulate entrapment by restricting water
flow. A test mat can also be used to cover the
suction outlet to simulate an entrapment event.
Jandy
Pro Series ePump
®
Technical Support
®
|
+ SVRS
Installation and Operation Manual
2.
After an entrapment is detected, the pump will
shut down, automatically releasing the vacuum
created by the pump.
3.
After the pump shuts down, reopen/remove
restriction to pump suction line. The pump will
attempt to restart after a shutdown period of
approximately four (4) minutes.
4.
Repeat three (3) times to verify proper adjustment
and operation.

Section 4. Operation

4.1

Start-up

WARNING
The SVRS feature on this pump is inactive up to
ten (10) minutes after power up. During this period,
the pump does not monitor blocked suction or
discharge system condition. Keep bathers out of
the pool when SVRS is not active, such as during
the first ten (10) minutes after power up.
CAUTION
Never run the pump without water. Running the
pump "dry" for any length of time can cause severe
damage to both the pump and motor and will void
the warranty.
If this is a new pool installation, make sure all piping
is clear of construction debris and has been properly
pressure tested. The filter should be checked for
proper installation, verifying that all connections and
clamps are secure according to the manufacturer's
recommendations.
WARNING
To avoid risk of property damage, severe personal
injury or death, verify that all power is turned off
before starting this procedure.
1.
Release all pressure from the system and open the
filter pressure release valve.
2.
Depending on the location of the pump, do one of
the following:
- If the pump is located below the water level of
the pool, open the filter pressure release valve
to prime the pump with water.
- If the pump is located above the water level of
the pool, remove the lid and fill the filter basket
with water before starting the pump.
3.
Prior to replacing the lid, check for debris around
the lid o-ring seat. Debris around the lid o-ring
seat will cause air to leak into the system and will
make it difficult to prime the pump.