Fireplace Installation
Wiring
dry and dust free location until
you are ready to install the
fireplace.
Hardwire Installation
The fireplace is packaged with a
two prong plug installed for plug-
in convenience. Hard wiring the
fireplace is also an option for any
installation.
WARNING: Do not attempt
to wire your own new outlets
or circuits. To reduce the risk
of fire, electric shock or in-
jury to persons, always use a
licensed electrician.
WARNING: Ensure that the
circuit on which the fireplace is
to be installed has the power
cut off at the service panel
until installation is complete.
1. Remove the partially reflective
8
HEATER
LINE
MOTOR
M
M
L1
120V~
N
60Hz
LED LIGHTS
LED LIGHTS
glass from the fireplace:
• Lay fireplace on its back.
• Remove two Phillips screws
from each of the two glass
brackets (Figure 2).
• Remove glass brackets.
• With one hand keeping pres-
sure on the partially reflective
Figure 2
Glass Bracket
DISPLAY
BOARD
FLAME COLOR
TOP LIGHT
SWITCH
LOG MEDIA
NTC
FAN
BOARD
NTC
LED LIGHTS
LED LIGHTS
Bracket Screws
Partially
Reflective Glass
www.dimplex.com