Authorized Personnel Maintenance; To Access Pump Motor; Solenoid/Solution Directional Valve Removal; Brush Motor Repair - Clarke IMAGE 20 I Libro De Instrucciones

Tabla de contenido
Page 28

AUTHORIZED PERSONNEL MAINTENANCE

To Access Pump Motor

1. Remove brush housing from machine. See "Brush Motor
Repair".
2. Remove pump ground wire from ground screw.
3. Disconnect pump electrical wires form machine harness.
4. Remove solution hoses by turning swivel nut counter
clockwise.
5. Remove four (4) mounting screws that secure pump motor
to solution tank.
6. Reverse procedures for installing new pump. Check wiring
diagram for proper connections when reinstalling electrical
parts.
Solenoid/Spray Valve Removal
1. Loosen screw in rear plate that secures recovery tank to
machine.
2. Raise and tilt recovery tank to the side.
3. Disconnect electrical lead from solution valve.
4. Disconnect solenoid from brush housing by press quick
disconnect coupling on top of brush housing.
5. Remove hoses by loosening hose clamps and pull hoses
from solenoid valve.
6. To reinstall, reverse procedure. Check wiring diagram for
proper connections when reinstalling electrical parts.

Brush Motor Repair

1. Tilt machine on handle or place machine upside down.
2. Pull brush adjustment rod out of adjustment holes.
3. Remove brush stop bracket by removing two (2) screws.
4. Remove two (2) brush pivot shoulder screws (3/16" Allen
Wrench) from sides of solution tank.
5. Pull brush housing away from solution tank far enough to
access wiring .
6. Disconnect wiring and place brush housing on bench.
7. Remove bottom plate by removing nine (9) 10-32 screws.
8. Remove motor and reverse procedure to reinstall.
9. Check wiring diagram for proper connections when reinstall-
ing electrical parts.
Clarke
®
Image 20 120V Operator's Manual
Tabla de contenido
loading

Este manual también es adecuado para:

Image 20 ixWash&rinse ergoex image 16 i 120vImage 16 ix 120v

Tabla de contenido