Urmet Sinthesi S2 Manual De Referencia página 26

Microaltavoz audio
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

If instead the door unit is configured as main unit, then the buttons are automatically associated to the column
0, which simplifies the installation of main units in single column systems.
Instead, if the door unit is configured as main unit and several columns are present in the system, an
association must be created between the buttons and the users of the different column proceed as follows:
Access advanced configuration by turning the two rotary switches to position 99 (the yellow LED will
light up).
Set the ID dip-switch to the code of the first column in the system (column 0 typically).
Press the button corresponding to user 0 of the selected column. All the subsequent buttons will be
automatically associated to the users of the column itself in sequence.
Repeat the operation on all the columns.
Reset the ID dip-switch in start position.
To quit advanced configuration, turn the two rotary switches to the door opening line and the guaranteed
conversation time setting positions. The yellow LED will go out.
6
P5÷P8
P9÷P12
1083/17 (1)
P1÷P4
P13÷P16
INPUT
OUTPUT
P5÷P8
P9÷P12
1083/17 (4)
P1÷P4
P13÷P16
OUTPUT
DS1083-056A
Tabla de contenido
loading

Este manual también es adecuado para:

1083/74

Tabla de contenido