HP3
English
A copy of the declaration of product conformity can be requested by filling in the form available
at the internet address:
5. Presentation - Proper use (Fig. 1)
HP3 units are modular refrigerated systems with air-cooled condensers and propeller fans, consisting
of 3 hermetic or semi-hermetic compressors of various strengths connected to each other and
assembled on a frame. The unit can be supplied with all the elements necessary for proper
performance, including: power and control panel, pressure transducers, pressure switches, and safety
devices.
The combination of various compressor models functioning in diverse ways and with diverse gases,
has allowed us to create a vast array of models that are able to satisfy most needs in terms of
operating power, operating temperature, safety accessories and electronic controllers.
6. Technical Data Page 6
Data is calculated for R404A, condensation temperature +50°C, evaporation temperature -10°C (TN)
and -35°C (BT), overheating 10K. With SCROLL compressors it is possible to further reduce sound
pressure by 10 dB(A), by requesting "SOUND SHELL" soundproofing casing as an option.
Project data
- Maximum Allowable Pressure:
- Maximum Allowable Operating Pressure:Pset =25 bar
- Maximum Permissible Temperature (high pressure):Ts max =+ 63°C Ts min = - 10°C
- Minimum Permissible Temperature (low pressure):Ts max =+ 43°C Ts min = - 35°C
- Coolant types (Group 2 Art. 9 97/23 EC Par. 2.2):R404A - R507A
7. Identification - Plate data (Fig. 2)
High
H
P Power
3 Multisystem 3 compressors
B Compressors brand
O Oil equalizer
-
Plant configuration
S Power Supply
N Field of use
4 Gas
C Electronic controller
Control panel accessories:
TN/BT if single plant;
TN if dual;
lower if multi-floor
3 No. compressors:
Compressor model
/
Upper part control device
C
if multi-floor
Control panel accessories
upper part
2 No. compressors, upper part
4
N
C
Compressor model
1
2
18
http://
www.arneg.it/conformity
Ps =28 bar
DESCRIPTION OF THE PLANT CODE FOUND ON THE RATING PLATE
B=Bitzer; C=DWM-Copeland DISCUS; D=Dorin; F=Frascold; I=DWM-Copeland STANDARD S=Copeland Scroll
0=Standard equalization
1=Equalization with "STANDARD" pipe
2=Equalization with "INBOX" pipe
3=Equalization with tube and oil separation with suction discharge
4=MECHANICAL oil level regulators with separator and oil reserve
5=ELECTRONIC oil level regulators with separator and oil reserve
6=ELECTRONIC oil level regulators with separator and incorporated oil reserve
S= 400-3-50; I= 240-3-50; E= 460-3-60; V= 240-3-60;
B=BT
D=DUAL Same floor
M=DUAL Multi-floor
N=TN
4=R-404A; 5=R-507A; 2=R-22
C=CAREL pCo3; D=DANFOSS AKC25H5; E=DANFOSS EKC331; I=CAREL IR32Z; K=DANFOSS EKC531; L=DIXELL XC440C;
M=CAREL Microrack; P=DANFOSS AK2-PC; U=UNIT 03
_=Standard
D=Differentials
I=Inverter
L=Inverter also on condenser
M=Phase monitor
R=Power Factor Correction
T=Differentials + Power Factor Correction
C=CAREL pCo3; E=DANFOSS EKC331; I=CAREL IR32Z; K=DANFOSS AKPC530 (prev. EKC531); L=DIXELL XC1015D; P=DANFOSS
AK2-PC
See control panel accessories
2; 3; 4
05060114 00 09/07/2010