To be integrated with a complete reading of the technical board
Installation and commissioning
• Installation by Dealer that released warranty and maintenance manual.
• Room ventilation.
• The smoke channel/chimney flue only receives the insert discharge.
• The smoke channel (INPELLET 54 connection/chimney flue) has:
maximum 2 curves – maximum 1 meter horizontal
• Combustion chamber outside the backflow area.
• The chimney flue is created with suitable materials (stainless steel recommended).
• In crossing any flammable materials (e.g. wood), all precautions have been taken to avoid fire.
Use
• Good quality, dry pellets used (max. moisture content 8%).
• The combustion chamber and ash compartment are clean.
• Glass must always be cleaned cold.
• The hatch must be properly closed.
• The combustion chamber must be properly inserted in the specific compartment.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, empty the combustion chamber prior to repeating ignition.
REMOTE TELEPHONE IGNITION (code 281900)
The insert can be remote ignited by connecting a telephone combiner to the electronic board (contact a Dealer).
OPTIONAL CABLE (code. 640560)
CLEANING ACCESSORIES (optional extras)
GlassKamin
(code 155240)
Used for cleaning the ceramic glass
CHECK LIST
OPTIONAL
35
Ash vacuum cleaner
without motor
(code 275400)
User for cleaning the hearth