Views; Errors - Key Automation CT-PAE Instrucciones Y Advertencias Para Su Instalación Y Uso

Central 24vdc para un motor de puerta automática corredera 24 vdc, con gestión de encoder
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.6 - Views

Views of red indicator LEDs on NC contacts, green indicator LEDs
on NO contacts turn on when activated (radar/open/close)
Pressing the M key displays the following in sequence:
The total number of cycles automatically performed, ex-
pressed in hundreds.
The partial number of cycles automatically performed, ex-
pressed in hundreds: this counter can be reset by holding
the OK button for two seconds until you hear a beep.
If display is switched off you press and hold the OK button (until you
hear a beep) other information can be displayed in real time:
Position of the door (in encoder counts).
The learnt run (in encoder counts).
The learned approach space at opening (in counts en-
coder).
The learned approach space at opening (in counts en-
coder).
4.7 – Errors
The following errors or warnings, if present, are displayed immedi-
ately after the operation mode:
Please note: Errors 3, 8 and 12 do not allow the operation of
the equipment; for each command (radar or other) you will
hear a double "beep" and the door remains stationary.
Please note: Errors 6 and 9 can only occur during a learning
operation.
If there any errors take place, the LED on the switch flashes, while
in the presence of error 04 (power outage), the LED on the switch
flashes at a lower frequency
Obstacle detected during closing. - The device operation
E 01:
continues normally.
Obstacle detected during opening. - The device opera-
E 02:
tion continues normally.
Faulty encoder. - Device locks and attempts to resume
operation only after being reset or turned off.
E 03:
No electric power. - The device continues its operation,
E 04:
as set by parameter "F".
Dead battery. - The device continues its operation nor-
E 05:
mally, as set by parameter "G".
Learnt run over maximum limit. - Device attempts to
E 06:
resume operation only after being reset or turned off.
Learning of weight failure - Device attempts to resume
operation only after being reset or turned off.
E 07:
Motor polarity reversed or encoder channels inverted. -
E 08:
Device locks and attempts to resume operation only after
being reset or turned off.
Relative weight over maximum limit. - Device attempts to
E 09:
resume operation only after being reset or turned off.
Motor voltage is over maximum allowed. - Device at-
E 10:
tempts to resume operation only after a new command.
Battery voltage only be displayed with parameter P=1
(in Volt).
Instant current (in 1/100 Ampere) if the door is moving.
The maximum current of the last movement when the door is
stopped.
Motor voltage (in Volt)
Current obstacle threshold (in 1/100 Ampere)
The codes of the last 16 errors are automatically visualized
with an interval of 1 second, numbered from 1 (the most recent)
to 16 (the least recent).
After 60 seconds of inactivity, the display returns to show the mode
of operation.
Pressing +, you can temporarily display the currently configured
weight class.
Power circuit overload protection occurred. Device at-
E 11:
tempts to resume operation only after a new command.
Error while reading or writing eeprom memory - Device
attempts to resume operation only after being reset or
E 12:
turned off.
E 13:
Monitored device 1 test failed command FOTO
Monitored device 2 test failed command FOTO
E 14:
Monitored device 1 test failed command FOTO RALL
E 15:
Monitored device 2 test failed command FOTO RALL
E 16:
Monitored device 1 test failed command STOP
E 17:
Monitored device 2 test failed command STOP
E 18:
Example of errors signal:
The first 2 numbers indicate the chronology of the errors (from 01
to 16). The last 2 indicate the type of error (according to the table)
AS
-
+
P2
P3
In the example in the figure, the error is
indicates
05
dead battery.
Other error examples as follows:
Last error
no electric power
Second to last error
Third to last error
Fourth to last error
OK
M
P4
P5
START
02
the last two
dead battery
obstacle detected during closing
obstacle detected during opening
EN
25
Tabla de contenido
loading

Tabla de contenido