4.1 - Electrical connections

WARNING - before making connections, verify that the system is not powered
CN1 Connector for 24 vac power transformer
AC
AC
CN2 Connector for batteries and 24V power accessories
FT-
-24V
+24V
-BAT
+BAT
If the battery is present (it is recommended to enable battery test P =
1), its voltage is monitored at start-up and then every 4 hours, momen-
tarily disconnecting the mains supply.
If the battery is broken, disconnected or dead, the equipment is turned
off briefly during the test and then it's turned on again.
This event will be automatically recorded indicating the failure of the
test through the message ERROR 5, the flashing of the manual
selector LED, and the automatic behaviour will be defined by parameter
G. The test will not be repeated, in order to avoid further shutdowns of the
equipment every 4 hours.
CN3 Connector for motor and electric lock
ELB
ELB
M2
M1
CN5 Connector for motor encoder
- ENC
A ENC
B ENC
+ ENC
20
AC Connector for 24 Vac power transformer
AC Connector for 24 Vac power transformer
N
L
T2A 230V
230Vac
50/60Hz
(Not used)
Negative for powering radar and accessories
Positive for powering radar and accessories
Negative battery connection
Positive battery connection
Electric lock Power 12 Vdc
Electric lock Power 12 Vdc
Motor Power 24 Vdc RED
Motor Power 24 Vdc BLACK
Negative for Encoder (black)
Signal A encoder (green)
Signal B encoder (yellow)
Positive for Encoder (red)
24V
12V
12V
1,2Ah
1,2Ah
Removing and inverting the cables in the
encoder connector, the door does not func-
tion.