2 -PRODUCT OVERVIEW

2.1 - Description of the control unit

The CT-PAE control unit is the most modern and efficient Key Au-
tomation control system for a 24 Vdc motor with double encoder,
integrated battery charging module, self-calibration, for automa-
tion of one or two sliding doors.
Misuse of the unit is prohibited.
3
2
1
11
Description of connections CT-PAE
1 - Power supply connector from transformer 24 Vac
2 - Batteries and power supply connection connector accessories 24V
3 - Motor and electric lock connection connector
4 - Interlock connection connector
5 - Motor encoder connector
6 - Commands and test connection connector
7 - Connector for start-stop and internal/external radar and photocells
8 - Power supply connector accessories 24V
2.2 - Description of manual selector SMNPAE
The manual selector permits variation of the control unit functioning modes
B
C
Description of connections SELCT-PAE
A - CN1 Connection block to be connected to CN9 on CT-PAE control unit
B - CN2 Telephone connector to be connected to EASY external pad
C - COM Manual selector for selecting functions
D - P1 reset button
E - DL1 error LED indicator
18
CT-PAE is equipped with a display that allows
easy programming
and constant monitoring of inputs; in addition, the
menu structure
allows easy setting of working time and operating
modes.
12
13 14 15
9 - Digital/manual selector connection connector
10 - Start button
11 - Safety fuses 2x15A
F1 Power transformer
F2 Power battery
12 - P2 button +
13 - P3 button -
14 - P4 button M (Menu)
15 - P5 button OK (Confirm)
16 - Commands and safety LED indicator
E
A
D
8
6
16
10
9
7
4
5