Important Safety Requirements - CORBERO CPCG602W Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Gas category
I2H(13)
Wok burner
Wok burner(midea)
Rapid burner
Semi rapid burner
Auxiliary burner
Gas category
I
LU,NL,DK,FI,SE,CY,CZ,EE,LT,MT,SK,SI,BG,IS,NO,TR,HR,HU,RO,IT,LV
3B/P(30)
I
BE,FR,IT,LU.IE,GB,GR,PT,ES,CY,CZ,LT,SK,CH,SI,LV
3+(28-30/37)
I
PL
3B/P(37)
I
3B/P(50)
DE,AT,CH,LU,SK
I
FR,IT,BE,NL,DK,IE,GB,GR,ES,PT,AT,FI,SE,CZ,EE,HU,LV,LT,SK,SI,IS,NO,CH,TR,BG,HR,RO
2H(20)
I
DE,LU,PL
2E(20)
I
BE,FR
2E+
I
NL
2L(25)
II
DE,PL,RO
2E3B/P
II
CH,CY,CZ,GB,GR,IE,IT,LT,PT,SI,SK
2H3+
II
AT,CH,CY,CZ,DK,EE,FI,GR,IT,LT,NO,RO,SE,SK,SI
2H3B/P
Note: when injectors are changed, the new one should be marked by the gas technician.
Appliance Class: 3
This appliance complies with the following E.E.C. Directives: 2006/95, 93/68, 2004/108 and 90/396.
0845-14

Important safety requirements

Provision for ventilation
The hob should not be installed in a bed sitting room with a volume of less than 20m³. If it is installed in a room of volume less than 5m³
an air vent of effective area of 110cm²is required. If it is installed in a room of volume between 5m³and 10m³, an air vent of effective
area of 50cm² is required, while if the volume exceeds 11m³no air vent is required. However, if the room has a door which opens
directly to the outside no air vent is required even if the volume is between 5m³ and 11m³
the same room, which should be consulted to determine the requisite air vent requirements.
Location
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom, shower room or garage.
Before making the cut out in the worktop ensures that there is a minimum distance of 55 mm between the rear edge of the hob and the
wall.
A minimum distance of 100 mm must be left between the side edges of the hob and any adjacent cabinets or walls.
The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm.
If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob.
The minimum distance combustible material can be fitted directly above the hob is 700 mm. (See Figure 4*)
Warning: The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that
the kitchen is well ventilated: keep natural ventilation holes open or install a mechanical ventilation device.
NG(G20)
Injector Dia.(mm)
I2H(20)/I2E
I2L(25)
(20)/I2E+
/
1.3
1.36
(0.317m3/h)
/
1.3
1.36
(0.317m3/h)
/
1.3
1.25
(0.288m3/h)
/
0.97
0.95
(0.168m3/h)
/
0.72
0.7
(0.096m3/h)
kw
Injector Dia.(mm)
I3B/P(30)/I
I3B/P(37) I3B/P(50)
3+
3.3
0.93
0.88
3.3
0.88
0.88
3.0
0.85
0.84
1.75
0.65
0.63
1.0
0.5
0.49
. If there are other fuels burning appliances in
3
LPG(G30)
kw
3.3
0.76
(240.9g/h)
3.3
0.8
(240.9g/h)
3.0
0.75
(219.0g/h)
1.75
0.58
(127.8g/h)
1.0
0.43
(73.0g/h)
6