INSTALLATION
6
INSTALLATION OF THE EMPTYING HOSE
For easy evacuation of the condensation water, the emptying hose must be inclined
downwards. The arrangement in diagrams 2 to 5 is incorrect.
Inclined
downwards
Water leak
•
If the emptying hose connected to the internal unit proves
to be too short, it can be extended using the hose provided in
the accessories.
•
If the emptying hose has to cross the house, it must be
enveloped with special thermal insulation materials.
7
Sealing the hole in the wall and fixing the pipe
•
Use mastic to seal the hole
in the wall.
•
Use the fixation clamp to fix
the pipe in position.
8
Wall fixation
• To set the unit in place on
the fixation plate, lower it onto
the top of the plate and then
press it downwards using a
rotational movement to clip it.
112500-504-E
Inclined
Stagnant water
upwards
Water leak
Internal unit
© FAR GROUP EUROPE 2004
49
air
Water leak
Plug with mastic
Fix the pipe with the clamp
24/01/05, 11:37
GB
50mm or more
above the ground
Emptying hose
Pipe ( ø15 cm ) in
hard PVC
Suppress the excess section
Plastic collar for
wall mounting
Screw