Best WC35 Serie Manual De Instrucciones página 10

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EXTERNAL BLOWER ELECTRICAL CONNECTIONS
Blower connection at hood:
1. Run 2-wire plus ground power cable from
the Exterior or In-Line Blower to the hood's
wiring box marked "motor connection".
2. Remove the cover from the wiring box and
remove one knockout.
3. Feed 6" of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector.
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground.
5. Replace the wiring box cover and screws.
make sure wires are not pinched between
the cover and box.
Exterior or In-line blower connection:
1. Make electrical connections at the exterior
or in-line blower (see instructions provided
with the exterior or in-line blower).
Power connection at hood:
1. Plug the power cord into the electrical wall
receptacle.
BOX MARKED
"MOTOR
CONNECTION"
BLOWER CONNECTION AT HOOD
- 10 -
Exterior or
In-Line blower
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
FIG. 5
Tabla de contenido
loading

Tabla de contenido