Makita DTWA070 Manual De Instrucciones página 10

Ocultar thumbs Ver también para DTWA070:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
Changing the longest workable time range
When changing the longest workable time range
from 2.5 to 3.6
Fig.11
1 .
P ress t h e setting button se v eral times until t h e in d i c ator
s h o w s " H I " an d number alternati v el y . T h is stan d s f or t h e
c urrent setting o f t h e longest w orkable time range.
2.
P ress an d h ol d t h e setting button until t h e number
in t h e ones pla c e starts blinking.
3.
S et t h e number in t h e ones pla c e b y pressing t h e setting
button briefly. Every time you press the setting button, the
in d i c ator s h o w s t h e number f rom " 0 " to " 9 " in a c y c le.
Measuring an actual operation ( Self-diagnosis)
NOTICE:
T h is f unc tion is av ailable by d ef ault. I f y ou h av e d isabled th e F ield S etting mod e on th e c omputer, enable
this function beforehand. Refer to the instruction manual of Makita Industry Tool Settings for how to configure.
Y ou c an measure t h e tor q ue le v el an d operating time o f an a c tual operation b y operating t h e tool. Measure d tor q ue
le v el an d time c an be use d f or su c h as ;
R epro d u c ing a tor q ue c ontrol te c h ni c o f a w ell-skille d w orker an d ;
A time re f eren c e f or t h e setting o f t h e s h ortest / longest w orkable time range.
Measuring the torque level and operating time
1 .
P ress t h e setting button se v eral times until " A d . " is d ispla y e d on t h e in d i c ator.
2.
P ress an d h ol d t h e setting button until t h e in d i c ator s h o w s " C h " .
3.
P er f orm t h e operation t h at y ou w ant to measure t h e operating time.
If you have configured the torque level, operate the tool until it stops in the Tightening Auto Stop mode.
If you have not configured the torque level (Free mode), operate the tool as necessary.
4 .
C h e c k t h e measure d result. P ress t h e setting button on c e to d ispla y t h e a c tual tor q ue le v el, an d press it one
more time to d ispla y t h e a c tual operating time.
E v er y time y ou press t h e setting button, t h e in d i c ator s h o w s " C h " , t h e number o f a c tual tor q ue le v el, an d t h e
number o f a c tual operating time in a c y c le.
5 .
P ress an d h ol d t h e setting button to e x it t h e S el f - d iagnosis.
NOTE: T h e T ig h tening A uto S top mo d e w orks e v en in t h e S el f - d iagnosis. I f y ou w ant to measure t h e tor q ue le v el
w it h out limitation, set t h e tor q ue le v el " F F " ( F ree mo d e ) an d per f orm t h e pro c e d ures abo v e.
NOTE: I f " - - " is d ispla y e d on t h e in d i c ator, t h e impa c t d i d not w ork or t h e tor q ue le v el is h ig h er t h an 4 0. I f " -.- " is
d ispla y e d in t h e in d i c ator, t h e operating time e x c ee d e d 9 . 9 se c on d s.
I n c ase t h e impa c t d i d not w ork : R emeasure t h e tor q ue le v el w it h longer w orkable time.
I n c ase th e torq ue lev el is h igh er th an 4 0: T h e tool c annot measure th e torq ue lev el. U se th e tool w ith h igh er torq ue range if av ailable.
I n c ase t h e operating time e x c ee d e d 9 . 9 se c on d s, t h e w orkable time range is not a v ailable.
Measuring e x ample :
If you configure the following setting, you can read the tool status.
C ase 1
Setting item
T orq ue lev el
W orkable time range
C ase 2
Setting item
T orq ue lev el
W orkable time range
Tool setting
23
sh ortest: 2.5 sec .
longest: 3.5 sec .
Tool setting
23
sh ortest: 2.5 sec .
longest: 3.5 sec .
4 .
P ress an d h ol d t h e setting button until t h e number
in t h e d e c imal pla c e starts blinking.
5 .
S et t h e number in t h e d e c imal pla c e b y pressing
the setting button briefly. Every time you press the
setting button, t h e in d i c ator s h o w s t h e number
f rom " 0 " to " 9 " in a c y c le.
6 .
P ress an d h ol d t h e setting button f or a f e w se c on d s.
NOTE: W h en y ou set t h e v alue larger t h an " 9 . 9 " f or
t h e longest w orkable time range, t h e in d i c ator s h o w s
" -.- " an d t h e longest w orkable time range be c omes
d isable d . T o input " -.- " , set t h e v alue to " 9 . 9 " , an d t h en
press t h e setting button w h en t h e number in t h e ones
pla c e is blinking.
Measured result
20
3.5
Measured result
23
3
10 ENGLISH
Diagnosis
T h e tool h as stopped by th e
setting of th e longest w orkable
time range ( 3.5 sec .) bef ore
it reac h es th e setting of th e
T igh tening A uto S top mod e
( torq ue lev el 23) .
Diagnosis
T h e tool h as stopped by th e
T igh tening A uto S top mod e
( torq ue lev el 23) bef ore it
reac h es th e setting of longest
w orkable time range ( 3.5 sec .) .
Tabla de contenido
loading

Este manual también es adecuado para:

Dtwa100Dtwa140Dtwa190

Tabla de contenido