Installation Procedure; Installation Parts - Haier AC12CS1ERA Manual De Instrucciones

Ocultar thumbs Ver también para AC12CS1ERA:
Idiomas disponibles
  • ES

Idiomas disponibles

Installation Procedure

Please ask the dealer or specialist to install, never try by the
users themselves. After the installation please be sure of the
following conditions.
WARNING:
Please call dealer to install the air-conditioner.
Incorrect installation may cause water leaking, shock and
fire hazard.
CAUTION:
Air-conditioner can't be installed in the environment
with inflammable gases because the inflammable gases
near air-conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
It easily cause electrical shock without circuit breaker.
Connect earthing wire.
Earthing wire should not be connected to the gas pipe, water
pipe, lightning rod or phone line, incorrect earthing may
cause shock.
Use discharge pipe correctly to ensure efficient
discharge.
Incorrect pipe use may cause water leaking.
Wiring
Air-conditioner should be equipped with special power supply
wire.
Location
Air-conditioner should be located in well-vented and easily
accessible place.
Air-conditioner should not be located in the following places:
(1) Places with machine oils or other oil vapours.
(2) Seaside with high salt content in the air.
(3) Near hot spring with high content of sulfide gases.
(4) Area with frequent fluctuation of voltage e.g. factory,
etc.
(5) In vehicles or ships.
(6) Kitchen with heavy oil vapour or humidity.
(7) Near the machine emitting electric-magnetic waves.
(8) Places with acid, alkali vapour.
Choose the following locations:
(1) Capable of supporting air conditioner weight, don't
increase operating noise and vibration.
(2) Hot vapour from outdoor unit outlet and operating noise
don't disturb neighbour.
(3) No obstacles around the outdoor unit outlet.
TV, radio, acoustic appliances etc. are at least 1 m far away
from the indoor unit, outdoor unit, power supply wire,
connecting wire, pipes, otherwise images may be disturbed
or noises be created.
As required, take measures against heavy snow.

INSTALLATION PARTS

The following installation parts are optional parts. Use them
as required.
Optional parts
Adhesive tape
Saddle (L.S) with screws
Heat insulation material
Putty
Earthing
Drain hose
Piping hole cover
Plastic clamp
11
SELECTING THE MOUNTING POSITION
Decide the mounting position with the customer as
follows:
(1) Install the indoor unit level on a strong wall, floor, ceiling
which is not subject to vibration.
(2) The inlet and outlet ports should not be obstructed.The
air should be able to blow all over the room.
(3) Install the unit near an electric outlet or special branch
circuit.
(4) Do not install the unit where it will be exposed to direct
sunlight.
(5) Install the unit where connection to the outdoor unit is
easy.
(6) Install the unit where the drain pipe can be easily installed.
(7) Take servicing etc. into consideration and leave the
spaces shown in the figure below. Also install the unit where
the filter can be removed.
WARNING:
Install at a place that can withstand the weight of the indoor and
outdoor units and install positively so that the units will not topple
or fall.
CAUTION:
(1)Do not install where there is the danger of combustible gas
leakage.
(2)Do not install near heat sources.
(3)If children under 10 years old may approach the unit, take
preventive measures so that they cannot reach the unit.
Under ceiling
Left
Indoor unit
30 cm
1.5m
or more
Ceiling
2 cm
or more
Indoor unit
Floor console
may be difference
Right
Left
30 cm
1.5m
or more
Outdoor unit
1.5m
Right
30 cm
or more
loading

Este manual también es adecuado para:

Ac18cs1eraAc24cs1era