5.
Maintenance
5.1
Cleaning
The charger's housing and display should only be
cleaned using a damp cloth and neutral cleansers.
Do not use any abrasive cleaning detergent nor rough
workshop cloths.
5.2
Wearing parts
Description
Mains cable
Charger cables
!
If the charger cables or mains supply cable have
been damaged they must always be replaced by
original cables; these are available from the after-
sales department of the manufacturer in question.
5.3
Disposal
The BSL 2470 is subject to the European
directive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
¶
Make use of the local return and collection
systems for disposal.
¶
Proper disposal of the BSL 2470 prevents
environmental pollution and possible
health hazards.
Robert Bosch GmbH
6.
Charge current with 12 Volt / 24 Volt batteries can be
adjusted to any level.
When the control is set to maximum battery charging
current and 230 V mains voltage, the charging currents
will record the following values:
R
In 12 V-mode with 12 V charge voltage the battery
charging current is max. 140 A arithm. and during a
start-assist measure (1 V / cell) the start-assist cur-
Order number
rent is max. 250 A arithm.
R
1 684 460 276
In 24 V-mode with 24 V charge voltage the battery
1 684 461 174
charging current is max. 88 A arithm. and during a
start-assist measure (1 V / cell) the start-assist cur-
rent is max. 220 A arithm.
Description
Charging characteristic
Maximum charge voltage at setting >15
°C
Maximum charge voltage at setting <15
°C
Charger cable 3 m
Function temperature range
Mains rated voltage
Mains rated frequency
Mains fuse system
Power consumption
Battery nominal voltage
Battery capacity
Dimensions (W x H x D)
Weight
Degree of protection (DIN EN 60529)
Protective category (DIN EN 61010-1)
Radio interference suppression
Interference degree of emission I
Workplace related
noise emission value (Lpa)
Maintenance | BSL 2470 | 19
Technical data
1 689 989 004
en
Specification
WU
2,3 V per cell
2,4 V per cell
16 mm
with fully
2
insulated charger ter-
minals
0 °C to 50 °C
230 VAC 10%
50 Hz
H 250 T 15A
2800 W
12 V / 24 V
36 Ah to 400 Ah
400 x 930 x 330 mm
approx. 29 kg
IP 20
I
VDE 0875
DIN 40839 or
ISO 7637 part 1 and
part 2
≤ 70 dB(A)
|
2014-01-15