Wearing Parts; Technical Data - Bosch BSL 2470 Manual Original

Equipo cargador rápido per baterías de 12/24 v
Ocultar thumbs Ver también para BSL 2470:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
5.
Maintenance
5.1
Cleaning
The charger's housing and display should only be
cleaned using a damp cloth and neutral cleansers.
Do not use any abrasive cleaning detergent nor rough
workshop cloths.
5.2

Wearing parts

Description
Mains cable
Charger cables
!
If the charger cables or mains supply cable have
been damaged they must always be replaced by
original cables; these are available from the after-
sales department of the manufacturer in question.
5.3
Disposal
The BSL 2470 is subject to the European
directive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of the BSL 2470 prevents
environmental pollution and possible
health hazards.
Robert Bosch GmbH
6.
Charge current with 12 Volt / 24 Volt batteries can be
adjusted to any level.
When the control is set to maximum battery charging
current and 230 V mains voltage, the charging currents
will record the following values:
R
In 12 V-mode with 12 V charge voltage the battery
charging current is max. 140 A arithm. and during a
start-assist measure (1 V / cell) the start-assist cur-
Order number
rent is max. 250 A arithm.
R
1 684 460 276
In 24 V-mode with 24 V charge voltage the battery
1 684 461 174
charging current is max. 88 A arithm. and during a
start-assist measure (1 V / cell) the start-assist cur-
rent is max. 220 A arithm.
Description
Charging characteristic
Maximum charge voltage at setting >15
°C
Maximum charge voltage at setting <15
°C
Charger cable 3 m
Function temperature range
Mains rated voltage
Mains rated frequency
Mains fuse system
Power consumption
Battery nominal voltage
Battery capacity
Dimensions (W x H x D)
Weight
Degree of protection (DIN EN 60529)
Protective category (DIN EN 61010-1)
Radio interference suppression
Interference degree of emission I
Workplace related
noise emission value (Lpa)
Maintenance | BSL 2470 | 19

Technical data

1 689 989 004
en
Specification
WU
2,3 V per cell
2,4 V per cell
16 mm
with fully
2
insulated charger ter-
minals
0 °C to 50 °C
230 VAC 10%
50 Hz
H 250 T 15A
2800 W
12 V / 24 V
36 Ah to 400 Ah
400 x 930 x 330 mm
approx. 29 kg
IP 20
I
VDE 0875
DIN 40839 or
ISO 7637 part 1 and
part 2
≤ 70 dB(A)
|
2014-01-15
Tabla de contenido
loading

Tabla de contenido