JET PUMP MOUNTED
ON HORIZONTAL TANK
GATE
VALVE
PRESSURE
SWITCH
DRAIN
NOTE: NO PRESSURE RELIEF VALVE SHOWN ON JET PUMP WITH IN-LINE DRAWING AND JET PUMP MOUNTED ON VERTICAL TANK DRAWING.
Setting the Tank Pressure
The tank pressure must be set 2 PSI lower than
the pump cut-on pressure. Check tank pressure
with a standard air gauge valve at the top of the
tank as needed.
Other Tank Installations
Where space is a critical factor, the in-line tank
may be used or the pump may be mounted on
HLWKHU WKH KRUL]RQWDO RU YHUWLFDO WDQNV 9DULRXV
installations are shown below. Also, to increase
tank capacity up to even industrial levels, multiple
tanks may be installed on the same line as shown
TO SYSTEM
RELIEF
VALVE
TO WELL
PRESSURE
SWITCH
JET PUMP WITH
IN-LINE TANK
TO
SYSTEM
PRESSURE
SWITCH
RTA
ADAPTER
DRAIN
to the right. Consult your local pump professional
for your particular installation.
8
JET PUMP MOUNTED
ON VERTICAL TANK
UNION
5(48,5('
CHECK
VALVE
SUCTION
PIPE
Figure 9