IO Link Data Dictionary
21.10.01.00125
Initial Settings
Blow off mode
69
0x0045
0
bLo
71
0x0047
0
Ou2
Output 2 function
73
0x0049
0
P n
Signal Type
74
0x004A
0
uni
Display Unit
75
0x004B
0
dLY
Output filter
76
0x004C
0
Eco
Eco Mode
79
0x004F
0
dIS
Display Rotation
Process Settings
Number of active profile
275
0x0113
P n
Production Setup Profile P0
68
0x0044
0
Ctr
Air saving function
78
0x004E
0
dCS
Disable continuous suction
100
0x0064
0
SP1
Switch Point 1
101
0x0065
0
rP1
Reset Point 1
102
0x0066
0
SP2
Switch Point 2
103
0x0067
0
rP2
Reset Point 2
106
0x006A
0
tbl
Duration automatic blow
107
0x006B
0
t 1
Permissible evacuation time
108
0x006C
0
L
Permissible leakage rate
Profile name
119
0x0077
0
Production Setup Profile P1
180
0x00B4
0
Air saving function
181
0x00B5
0
Disable continuous suction
182
0x00B6
0
Switch Point 1
183
0x00B7
0
Reset Point 1
184
0x00B8
0
Switch Point 2
185
0x00B9
0
Reset Point 2
186
0x00BA
0
Duration automatic blow
Permissible evacuation time
187
0x00BB
0
188
0x00BC
0
Permissible leakage rate
199
0x00C7
0
Profile name
Production Setup Profile P2
200
0x00C8
0
Air saving function
201
0x00C9
0
Disable continuous suction
202
0x00CA
0
Switch Point 1
203
0x00CB
0
Reset Point 1
204
0x00CC
0
Switch Point 2
205
0x00CD
0
Reset Point 2
206
0x00CE
0
Duration automatic blow
207
0x00CF
0
Permissible evacuation time
Permissible leakage rate
208
0x00D0
0
219
0x00DB
0
Profile name
Production Setup Profile P3
220
0x00DC
0
Air saving function
Disable continuous suction
221
0x00DD
0
222
0x00DE
0
Switch Point 1
223
0x00DF
0
Reset Point 1
224
0x00E0
0
Switch Point 2
225
0x00E1
0
Reset Point 2
Duration automatic blow
226
0x00E2
0
227
0x00E3
0
Permissible evacuation time
228
0x00E4
0
Permissible leakage rate
239
0x00EF
0
Profile name
Observation
Monitoring
Process Data
40
0x0028
0
Process Data In Copy
41
0x0029
0
Process Data Out Copy
64
0x0040
1
Vacuum Value
Vacuum Value LO
64
0x0040
2
64
0x0040
3
Vacuum Value HI
65
0x0041
1
Pressure Value
Pressure Value LO
65
0x0041
2
65
0x0041
3
Pressure Value HI
66
0x0042
1
Supply Voltage
66
0x0042
2
Supply Voltage LO
66
0x0042
3
Supply Voltage HI
Evacuation time t
148
0x0094
0
Evacuation time t
149
0x0095
0
160
0x00A0
0
Leakage rate
161
0x00A1
0
Free flow vacuum
Max. reached vacuum in last cycle
164
0x00A4
0
165
0x00A5
0
Min. pressure during last cycle
Communication Mode
Communication Mode
564
0x0234
0
Counters
Vacuum on counter
140
0x008C
0
cc1
Valve operating counter
141
0x008D
0
cc2
142
0x008E
0
cc3
Condition monitoring counter
143
0x008F
0
ct1
Erasable vacuum on counter
144
0x0090
0
ct2
Erasable valve operating counter
145
0x0091
0
ct3
Erasable condition monitoring counter
J. Schmalz GmbH
1 byte
0 2
1 byte
0 1
1 byte
0 1
1 byte
0 3
2 byte
0 999
1 byte
0 2
1 byte
0 1
1 byte
1 byte
0 2
1 byte
0 1
2 bytes
999 > SP1 > rP1
2 bytes
SP1 > rP1 > SP2 rw
2 bytes
rP1 > SP2 > rP2
2 bytes
SP2 > rP2 >= 10 rw
2 bytes
10 9999
2 bytes
0 9999
2 bytes
0 999
1...32 bytes
1 byte
0 2
1 byte
0 1
2 bytes
999 > SP1 > rP1
2 bytes
SP1 > rP1 > SP2 rw
2 bytes
rP1 > SP2 > rP2
2 bytes
SP2 > rP2 >= 10 rw
2 bytes
10 9999
2 bytes
0 9999
2 bytes
0 999
1...32 bytes
1 byte
0 2
1 byte
0 1
2 bytes
999 > SP1 > rP1
2 bytes
SP1 > rP1 > SP2 rw
2 bytes
rP1 > SP2 > rP2
2 bytes
SP2 > rP2 >= 10 rw
2 bytes
10 9999
2 bytes
0 9999
2 bytes
0 999
1...32 bytes
1 byte
0 2
1 byte
0 1
2 bytes
999 > SP1 > rP1
2 bytes
SP1 > rP1 > SP2 rw
2 bytes
rP1 > SP2 > rP2
2 bytes
SP2 > rP2 >= 10 rw
2 bytes
10 9999
2 bytes
0 9999
2 bytes
0 999
1...32 bytes
4 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
0
2 bytes
1
2 bytes
2 bytes
2 bytes
2 bytes
1 byte
4 bytes
4 bytes
4 bytes
4 bytes
4 bytes
4 bytes
rw
0
rw
0
rw
0
rw
0
rw
10
rw
0
rw
0
ro
rw
1
rw
0
rw
750
600
rw
550
540
rw
200
rw
2000
rw
250
rw
***
rw
1
rw
0
rw
750
600
rw
550
540
rw
200
rw
2000
rw
250
rw
***
rw
1
rw
0
rw
750
600
rw
550
540
rw
200
rw
2000
rw
250
rw
***
rw
1
rw
0
rw
750
600
rw
550
540
rw
200
rw
2000
rw
250
rw
***
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
2 of 3
J. Schmalz GmbH
Johannes Schmalz Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403 0
Fax: +49(0)7443/2403 259
0 = Externally controlled blow off ( E )
1 = Internally controlled blow off – time dependent (I t)
2 = Externally controlled blow off – time dependent (E t)
0 = NO
1 = NC
0 = PNP
1 = NPN
0 = mbar
1 = kPa
2 = inHg
3 = psi
Unit: 1 ms
0 = off
1 = on (full eco mode with display switching off completely)
2 = Lo (medium eco mode with display dimmed to 50%)
0 = Standard
1 = Rotated
Number of the active profile: 0 3
0 = not active (off)
1 = active (on)
2 = active with supervision (onS)
0 = off
1 = on
Unit: 1 mbar
Unit: 1 mbar
Unit: 1 mbar
Unit: 1 mbar
Unit: 1 ms
Unit: 1 ms. No t 1 Warning if set to 0
Unit: 1 mbar/sec. No L Warning if set to 0
Profile P 1
(selected by PD Out 0 Profile Set = 1)
Profile P 2
(selected by PD Out 0 Profile Set = 2)
Profile P 3
(selected by PD Out 0 Profile Set = 3)
Copy of currently active process data input
Copy of currently active process data output
Actual vacuum value
Lowest measured vacuum value since power up
Highest measured vacuum value since power up
Actual pressure value (unit: 1 mbar)
Lowest measured pressure value since power up
Highest measured pressure value since power up
Supply voltage (unit: 0.1 Volt)
Lowest measured supply voltage since power up
Highest measured supply voltage since power up
Time from start of suction to SP2 (unit: 1 ms)
Time from SP2 to SP1 (unit: 1 ms)
Leakage of last suction cycle (unit: 1 mbar/sec)
Last measured free flow vacuum (unit: 1 mbar)
Maximum vacuum value of last suction cycle
Minimum input pressure during suction phase of last cycle
0x00 = SIO mode
0x10 = IO Link revision 1.0 (set by master)
0x11 = IO Link revision 1.1 (set by master)
Not erasable (stored every 1000 counts)
Not erasable (stored every 1000 counts)
Not erasable (stored every 1000 counts)
Can be reset by System Command "Reset erasable counters" (stored every 1000
counts)
Can be reset by System Command "Reset erasable counters" (stored every 1000
counts)
Can be reset by System Command "Reset erasable counters" (stored every 1000
counts)
SCPMi
14.06.2019
SCPMi Data Dictionary
Tabla de contenido
loading

Este manual también es adecuado para:

Scpmi 10 s04 nc m8-6 blt

Tabla de contenido