Assembly And Starting; Replacing The Power Cable - Parkside PKO 270 A1 Manual De Instrucciones

Ocultar thumbs Ver también para PKO 270 A1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

7. Assembly and starting

Important!
Remove the transportation braces (bet-
ween the compressor pump and clad-
ding, see Fig. 7) prior to initial start-up.
If the transportation braces are not re-
moved, heat can build up and cause the
compressor to ignite.
Important!
You must fully assemble the appliance
before using it for the fi rst time!
You will require the following tools for assembly
and installation:
2 x open-ended wrench size 13 mm (not inclu-
ded)
7.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.
7.2 Fitting the supporting foot (8)
Fit the supplied supporting foot as shown in Figure
6.
7.3 Fitting the air fi lter (15)
Remove the transportation stop (B) and screw the
air fi lter (15) to the equipment. (Fig. 7, 8).
7.4 Changing the transportation cover (A)
Remove the transportation cover from the oil fi ller
opening (21) and insert the supplied oil sealing
plug (16) into the oil fi ller opening. (Fig. 9, 10.)
7.5 Mains connection
The compressor is equipped with a mains
cable with shock-proof plug. This can be
connected to any 230V ~ 50 Hz shock-proof
socket which is protected by a 16 A fuse.
Before you use the machine, make sure that
the mains voltage is the same as the operating
voltage (see the rating plate).
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
At low temperatures below +5°C, sluggish-
ness may make starting difficult or impossible.
Anleitung_4010364_LB5.indb 51
Anleitung_4010364_LB5.indb 51
GB/MT
7.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (17) upwards to switch
on the compressor. To switch off the compressor,
press the ON/OFF switch down.
7.7 Setting the pressure (Fig. 1-3)
Use the pressure regulator (3) to set the pres-
sure on the pressure gauge (5).
The set pressure can be drawn from the quick-
lock coupling (4).
The vessel pressure can be read off the pres-
sure gauge (6).
The vessel pressure is drawn from the quick-
lock coupling (20).
7.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
7.9 Fitting the compressed air hose
(Fig. 1, 3)
Use the compressed air hose (14) if you intend
to carry out work at a greater distance from the
compressor. To do so, connect the nipple (H)
on the compressed air hose to one of the quick-
release couplings (4, 20). Then attach the com-
pressed air tool to the quick-release coupling (G)
on the compressed air hose.

8. Replacing the power cable

If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel to
avoid danger.
- 51 -
17.01.13 13:35
17.01.13 13:35
Tabla de contenido
loading

Tabla de contenido