EdilKamin H2OCEANO 15 - 15/CS Instalación Uso Y Mantenimiento página 38

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
SYSTEM FOR A CLOSED TANKINSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE - ONLY HEATING USING
Elec-
tricity
Mains
NB: Essential safety connections
Kit 5 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the
product to be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted
by the thermo- replace.
Electrical Connections
Power Supply
230 Vac
Circulator
3-way
valve
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THIS TO FUNCTION PROPERLY
Regulator
(included in the kit)
Fuse
Display
20 - 80° C
Valve Setting
Circulator enabled
Overheating alarm
3-way valve
20 - 80° C
Circulator Setting
1 1" Ball Valve
2 Thermal Relief Valve (72940)
3 Pressure Relief Valve (284220)
4 Circulator (219660)
5 Fittings with 1" Check Valve (284180)
6 ¾" Male 3-way Solenoid Valve (283690)
7 Fittings
9 Temperature Relief Valve Nozzle
10 Closed Expansion Tank (283680)
12 ½" Thermometer Well + Sensor (175960)
13 Electronic Regulator (220780)
14 3/8" Automatic Relief Valve (284150)
15 1/4" Manual Relief Valve (284170)
16 Manometer (269590)
A Fireplace Flow
B System return
C Fireplace Return
E Pressure Relief Valve
G Temperature Relief Valve
OFF
OFF
ON
ON
Enable
Disable
Acoustic
Alarm
Sensor (insert in the
appropriate well)
- 38
-
KIT 5
AL:
Water Mains Supply
C:
Filling/Top-Up Section
EV:
3-way Solenoid Valve
NA:
Normally Open
NC:
Normally Closed
GR:
Filling unit
Ja:
Automatic Relief Valve
Jm:
Manual Relief Valve
MAN:
Manometer
MI:
System Flow
P:
Pump (circulator)
RA:
Radiators
RE:
Electronic Regulator
RI:
System Return
S:
Drain
ST:
Temperature Sensor
V:
Ball Valve
Vec:
Closed Expansion Tank
VR:
Check Valve
VSP:
Pressurised Safety Valve
VST
Thermal Relief Valve
SELECTOR FUNCTIONS
Selector: OFF
Everything is switched off
Selector: MAN
Driven Circulator
Valve is set
Selector: AUTO
Circulator is set
Valve is set
Alarm selection
No acoustic signal in the
OFF position
KIT 5
code 280590