Stopping The Tool; Routine Maintenance - CAMPAGNOLA POWER 58 Manual De Uso

Ocultar thumbs Ver también para POWER 58:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Start the tool without the power saver function inserted. The ON red led light (9) does not flash.
WARNING!
Please find all the indications and warning about the lithium battery use in the enclosed battery instructions.
When starting the power unit, the harvesting head assembled on the extension pole begins moving immedi-
ately. Be very careful when positioning the tool. It shall be far from people and things. Neglecting this warning
could creating dangers for the operator.
5 TROUBLESHOOTING
5.1
Starting the tool
Before starting the tool, wear protective clothing as shown in the picture and check that all safety and protection systems
are functioning and assembled correctly.
Hold the tool with one hand on the extension pole near the handgrip. With the other hand turn on the ON-OFF switch
(7).
The tool is ready for use.
WARNING!
The tool shall be used for the purposes described in par. "product description" only. Other uses could cause
injuries and/or damages.
Start the tool only when inserted between the branches. Improper use causes greater wear-and-tear and it
does not allow to save the battery power.
5.2

Stopping the tool

The tool must always be switched off at the end of any working session:
Select the OFF mode of the switch (7).
Lean the tool without leaving its weight on the rakes and without bending or tensioning the connector and the power
supply cable (14-15).
Do not squash the cable (14-15) by putting weights or the tool onto it.
5.3
Troubleshooting.
WARNING!
All special maintenance operations shall be carried out only by well-trained personnel.
FAULT
The tool does not work
The tool is not powerful enough
Temporary tool stopping during the
use
The harvesting head does not move
MAINTENANCE
6
6.1

Routine maintenance

WARNING!
Before any routine maintenance operations, select the OFF mode of the switch (7) and disconnect the ca-
ble (14-15) from the tool.
All maintenance operations which are not described in this manual shall be carried out only by Authorized
Service Points.
Routine maintenance operations can be carried out by the operators.
6.1.1
General
Before any routine maintenance operation:
Select the OFF mode of the switch (7).
Wear protective gloves.
Pag. 24
CAUSE
Flat battery
Flat battery
Motor overheating due to thick
trees.
Exceeded current limits
Wrong connection of the extension
pole with the power unit
REMEDY
Re-charge the battery
Re-charge the battery
Get out of the tree, wait for the automatic
unlocking phase and start the tool again.
Remove the extension pole and check
the insertion of the motor connection in
the extension pole fitting.
Use and Maintenance Manual – Original
Instructions Rev.: 00, Data 23/11/2018