5.

Preparing the installation cavity

m
WARNING
Assure that there are no electrical wires or plumbing
in the area which the screws could penetrate.
Risk of injury and damage!
NOTE
– 2 anti-tip-brackets are required for each appliance.
– In some installations the sub-flooring or finished floor
may necessitate angling the wood screws used to
fasten the anti-tip-brackets to the back wall.
– The supplied set contains fastening screws for
various applications. Select the fastening screws
according to the local conditions.
– If the supplied fastening screws do not permit
secure attachment of the anti-tip brackets and
therefore the appliance, another method must be
used to attach the anti-tip brackets securely.
Specify the attachment points of the anti-tip-brackets.
Specify the detailed dimensions according to the
section on "Installation dimensions".
If the installation cavity is deeper than the appliance,
place a solid wooden beam behind the anti-tip-brackets
and attach securely to the base or the wall.
The length of the wooden beam is equal to the width of
the installation cavity!
If possible, always screw the wooden beam to existing
studs on the rear panel of the cavity.
16
Wood floor application
Use the wooden screws provided, see overview diagram
m
"Use the screws in the screws set".
Drill pilot holes:
1
/
" (3 mm) for the (5 x 60 mm) wooden screws
8
5
/
" (2 mm) for the (4 x 15 mm) wooden screws
64
Being certain the screws penetrate through the flooring
and into the wall plate a minimum of
Attach the anti-tip-bracket completely. Be sure screws
hold tight.
Concrete floor applications
m
Always wear safety glasses and other necessary
protective devices or apparel when installing or
working with anchors.
Risk of injury!
Not recommended for use in light-weight masonry material
such as block or brick.
Not recommended for use in new concrete which has not
had time to cure.
Do not use core drills to drill holes for this anchor.
Use concrete anchor M8 and M8 srew. Additional use the
wooden screws provided, see overview diagram "Use the
screws in the screws set".