WARNING: Spinel S.r.l. does not acknowledge any failure due to a lack of routine
maintenance of water softener according to procedures hereby described.

CAPSULE HOLDER ADJUSTMENT

SPINEL S.r.l. adjusts all capsule holders during quality tests before dispatch.
If there is any leak from the top of the capsule holder, it will be necessary to adjust it manually as
follows:
WARNING: carry out this operation only when the machine is cold
ADJUSTMENT OF THE UPPER CAPSULE HOLDER:
Once the front has been tilted up to give access to the capsule holder, proceed as follows:
Insert a 4mm diameter lever in one of the holes of the upper capsule holder;
Turning to the left will increase the tightening strength and turning to the right will decrease the
tightening strength.
For adjustment purpose, never move the capsule holder away from the upper surface too much (do
not unscrew more then ¾)
If the adjustment needs to be greater, tighten the upper capsule holder and use the screw on the
bottom capsule holder
If the leak is not repaired, inspect the upper capsule holder silicon rubber and replace if necessary.
However, these operations should be carried out by authorised personnel, using original SPINEL
s.r.l. spare parts.
+ tightening strength

SPARE PARTS

Replace components only with ORIGINAL SPINEL S.r.l. SPARE PARTS, available in all Spinel
service centres. SPINEL S.r.l. accepts no liability for failures of machines type JASMINE if spare
parts supplied by others are employed.
All repairs should be carried out only in our service centres and/or by authorised qualified staff
only.
44
- tightening strength
Picture. 5 - Adjustment of capsule holder
Spinel S.r.l.