Elite SI 9200 MP Manual De Instrucciones página 44

Soldador tipo inversor multi proposito auto-volt 110/220v (95-270v) de 200 amperios
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Maintenance
Routine and periodic maintenance
WARNING!
ELECTRIC SHOCK CAN KILL
Turn the input power OFF at the mains switch and remove mains plug from socket
before working on this equipment.
Have a qualified electrician install & service this equipment.
Allow machine to sit for 5 minutes minimum after disconnection from mains power to
allow the power capacitors to discharge before working inside this equipment.
Do not touch electrically live parts
1. Periodically (3-6 months depending on use / environment), remove the side/top
panels of machine and clean out machine with a low pressure dry air line paying
particular attention to PC Boards, Fan blades and switchgear.
2. Inspect input and output cables & hoses for fraying and cuts, replace if damaged
present
3. Keep mig torch and earth cables in good condition
4. Clean air vents to ensure proper air flow and cooling