AC waveform Penetration (only for TIG AC see FIGS
76 and 77 and AC WAVEFORM table). Selection of
the waveform suitable for penetration.
•
AC waveform Cleaning (for TIG AC only see FIGS 78
and 79 and AC WAVEFORM table). Selection of the
waveform suitable for cleaning.
•
AC frequency (only for TIG AC see FIGS. 80 and 81).
Adjusts the frequency of the alternating current.
•
AC balance (only for TIG AC see FIGS. 82 and 83).
Adjusts the percentage of the half-wave penetration.
Positive value better penetration, negative value bet-
ter cleaning.
•
AC amplitude adjustment (for TIG AC only)
•
Mix Duty-cycle (for TIG AC only See Figures 107 and
108)
•
Advanced parameters (see table).
MMA process (see chapter 15)
•
Current set point (main current FIGS 84 and 85)
•
Hot Start (Hot start current see FIGS. 86 and 87)
•
Hot Start Time (see FIGS. 88 and 89)
•
Arc force (see FIGS 90 and 91)
•
Antistick (see FIGS.92 and 93)
•
CUT OFF voltage (MMA DC only FIGS. 94 and 95)
•
VRD Vacuum voltage reduction ( FIGS 96 and 97)
7.4 SETTINGS (FIG. 45 )
7.4.1 CLOCK SETTING (FIG. 46-47).
Select and confirm the choice with the knob. Set date
and time and confirm.
7.4.2 LANGUAGE (FIG. 48).
Select and confirm the choice with the knob. Set the de-
sired language and confirm.
7.4.3 USER INTERFACE STYLE (SEE FIG. 50-51).
Select and confirm the choice with the knob. Set the de-
sired interface.
SQUARE
AC
WAVEFORM CLEANING
SINE
AC
WAVEFORM CLEANING
TRIANGULAR
AC
WAVEFORM CLEANING
A
B
Arc noise -
Cleaning -
20
WAVEFORM TABLE
SQUARE
AC
PENETRATION
WAVEFORM
A
B
C
D
E
5-
5-
5-
1-
A
B
C
D
E
3-
3-
5-
2-
A
B
C
D
4-
1-
5-
3
C
D
Warm -
Arc concentration -
7.4.4 MEASUREMENT UNIT (FIG. 52-53). Select and
confirm the choice with the knob. Set the desired meas-
urement unit.
7.4.5 DISPLAY PANEL LOCK (FIG. 54-55). Select and
confirm the choice with the knob. Select and confirm the
display panel lock.
7.4.6 USE OF THE PIN CODE (FIG. 56-57). Select and
confirm the choice with the knob. Select and confirm the
use of the Pin.
7.4.7 USB MANAGEMENT (SEE FIG. 58-59).
Select and confirm the choice with the knob. Select and
confirm the choice among: Removal - Update Firmware
and install options.
7.4.8 LAN SETUP (FIG.62-63).
Select and confirm the choice with the knob. Select and
confirm choicesanopola. Selezionare e confermare le
scelte.
8 V SECTOR. AC WAVEFORM (FIG. 98)
In this screen you can select and modify multiple sizes of
the 2 penetration and cleaning half-waves. Turn the knob
to highlights in BLUE the function penetrating or cleaning
and then press it to highlights in RED the function chosen
to enable its available sizes . The selectable and modifi-
able sizes are:
•
Both penetration and cleaning waveform (see FIG.
99)
•
AC balancing (FIGS 100 and 101)
•
The AC frequency (FIGS 102 and 103)
•
The amplitude adjustment AC (FIGS 102 and 103)
9 SECTOR Z. TIG MIX AC+DC (FIG. 106)
By selecting this function, alternating direct current and
alternate current and can be modified (FIGS. 107 and
SINE
AC
PENETRATION
WAVEFORM
A
B
C
3
3-
5-
3-
A
B
C
5
1-
3-
3-
A
B
C
2-
1-
3-
E
Electrode shape saving -
TRIANGULAR
WAVEFORM
D
E
A
B
2-
3
4-
D
E
A
B
3-
5
2-
D
E
A
B
4-
1
3-
N
= 1 (min.) ÷ 5 (max.)
AC
PENETRATION
C
D
E
5-
1-
3-
3
C
D
E
3-
1-
4-
5
C
D
E
1-
1-
5-
1