- Fix the range hood supports at the bottom of the unit after checking for ver-
tical and horizontal alignment (see ill.2).
- Find installation type for outside exhaust version:
a) With motor unit (UM) (MU) fixed on the range hood: remove frontal blind
plug TC (BP) (see ill. 3 a). Define the direction of air outlet by rotating the
FL flange of the motor unit. Fix UM (MU) to the range hood according to ill.
3b (top, bottom or side outlet). Connect the UM (MU) motor outlet to the
air discharge duct.
b) Remote motor positioned in technical compartment protected by atmos-
pheric agents inside the residence: define the type of air outlet:
- Side or bottom with 90x220 mm rectangular piping (ill. 4a). Check that
the blind plug TC (BP) is mounted on the range hood, remove the rectan-
gular plug corresponding the the desired outlet and mount the supplied
flange for rectangular pipe FR (ill. 4b). Fix the FM flange on UM (MU) and
place UM (MU) in the desired position. Connect the range hood outlet to
the UM (MU) inlet with suitable piping and connect the UM (MU) motor
outlet to the air discharge duct.
- Front or side with 150 mm diameter circular piping (ill. 4c). Remove the
blind plug TC (BP), mount the flange FC on the range hood, fix the flange
FM on UM (MU) and place UM (MU) in the desired position. Connect
the range hood air outlet to the UM (MU) inlet with suitable piping and
connect the UM (MU) motor outlet to the air discharge duct.
Comply with current regulations for air discharge.
c) Recirculation version: in this version, the cooking fumes are reintroduced
into the environment after being purified by the carbon filters located in the
metal filters compartment. For their location see section H2. Mount UM
(MU) as indicated in ill. 3b and connect the UM (MU) motor outlet to the
filter that discharges towards the kitchen interior environment, set on the
appliance containing the range hood.
- Make electrical connections between electronic box SC and the range hood
connector block according to the diagram in ill. 5.
- Fix electrical box SC in a suitable position at the bottom of the unit.
- Connect the motor cable to the power supply in compliance with current
regulations.
23