by varying the motor speed. If the motor is stopped with key 2, the function will automatically
deactivate. When the timer function is active, it is possible to deactivate it by pressing key 1.
Filter Reset: Every 30 hours of extractor fan operation, the filter signal will activate (steady red light).
With motor and light switched off and by applying prolonged pressure on the T1 key, the sig-
nal will be annulled and the shutter will open to access the filters. During this state it is not
possible to activate the motor and the T2.. T5 keys are inhibited. Once the filters have been
repositioned, applying prolonged pressure on the T1 key will close the shutter and the T2..T5
keys will be enabled again.
Opening of mobile part: When all the LEDs are switched off (light and motor off), applying prolonged
pressure on the key will enable to open the mobile part of the range hood for maintenance
operations. In this state it is not possible to activate the motor, T2..T5 keys are inhibited. T1
key is enabled.
Closure of mobile part: To exit the state with mobile part open and motor off, apply prolonged pressure
on the T1 key. The red T1 signal will switch off and from this moment the T2..T5 keys will be
enabled again.
2: 1° (1ST) / OFF - RECIRCULATION FUNCTION
1° (1st) / OFF: If the motor is stopped or at a different speed from the 1° (1st), pressing the key will activate
the 1° (1st) speed, and the T2 key will light up. If the mobile part is closed, it will open, and the
extractor fan will activate after a few seconds. During opening of the mobile part, the T2..T5
key will be deactivated. If the motor is at 1° (1st) speed, pressing the key will stop the extractor
fan and the T1 key will switch off. If the lights are turned off, the mobile part will be closed.
Recirculation Function: When the motor is turned off, applying prolonger pressure on the T2 key will
activate the recirculation function, and the mobile part will open. The T2 key will flash. During
the recirculation function (24 hour duration), the range hood will remain active for 1 hour at
1° (1st) speed, then it will stop for 3 hours and reactivate for another hour. These cycles are
repeated until timeout.
With activation of this function, other speeds may not be selected. To deactivate this function,
keep the T2 key pressed for at least 3 seconds.
3: 2° (2ND) SPEED
If the motor is at a different speed from the 2° (2nd), pressing the key will activate the 2° (2nd)
speed, and the T3 key will light up. If the motor is stopped, the key is disabled.
4: 3° (3RD) SPEED
If the motor is at a different speed from the 3° (3rd), pressing the key will activate the 3° (3rd)
speed, and the T4 key will light up.
If the motor is stopped, the key is disabled.
5: 4° (4TH) SPEED
If the motor is at a different speed from the 4° (4th), pressing the key will activate the 4° (4th)
speed, and the T5 key will light up.
If the motor is stopped, the key is disabled.
The 4° (4th) speed is timed; if the user does not change the speed, the motor will remain in 4°
(4th) for 14 minutes and then shift into 3° (3rd). The T5 key will switch off and the T4 key will
light up.
6: LIGHT - REMOTE BINDING
Light:
Briefly pressing key T6 will turn the light on and off. The T6 key will light up if the light is on. If
the mobile part is closed, it will open, and the light will switch on after a few seconds.
Remote Binding (optional): With motor and light turned off, applying prolonged pressure on the T6 key
will activate remote binding mode. The T6 Key will flash for a maximum of 10 seconds. During
flashing, at least one radio control key must be pressed. The function will deactivate upon
completion of the 10 seconds, or earlier if a compatible remote control is detected.
KEY PRESSURE MANAGEMENT:
Prolonged pressure = finger pressed on key for at least 3 seconds, the function activates during pres-
sure.
22