Check that the wires inside the range hood are not disconnected or cut; if this is the case,
contact your nearest service centre. The electrical connections must be performed by quali-
fied personnel.
The connections must be performed in compliance with the legal standards in force. Check
that the relief valve and the electrical system are able to support the load of the appliance (see
the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case, "standardised"
plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue wire must be used for the neutral,
- the brown wire must be used for the phase; the cable must not come into contact with hot
parts (over 70°C).
- fit a plug that is suitable for the load to the power cable, and connect it to a suitable power
outlet.
For appliances that come supplied with cable and plug please ensure they are plugged into a
circuit suitable for this appliance.
Please refer to a qualifed person. (See technical specifications in point B).
The manufacturer declines all liability if the safety standards are not observed.
E
RANGE HOOD WITH OUTSIDE DISCHARGE
In this version, the fumes and steam from the kitchen are conveyed outside through an exhaust
duct.
The exhaust conveyor that protrudes from the upper part of the range hood must be connected
to a duct that carries the fumes and steam outside. In this version, the charcoal filters, if fitted,
should be removed; to do this, see the instructions in point F. There must be adequate ventila-
tion of the room when the range hood is used at the same time as appliances burning gas or
other fuels, according to the standard.
Deviation for Germany:
When the range hood and appliances supplied with energy other than electricity are simulta-
neously in operation, the negative pressure in the room must not exceed 4 Pa (4x10 E-5 bar).
F
HOOD VERSION WITH INTERNAL
RECIRCULATION (filtering)
Standard hood not set for carbon filter To switch the hood from exhaust to filtering, the hood
body must be combined with the new Slim motor unit (codice KACL.784) and Carbon-Zeo filter
structure kit ( code KACL.930) available as optional.
For the filtering version configuration see fig. F.
G
OPERATION
1: TIMER - FILTER RESET - SHUTTER OPENING - SHUTTER CLOSING
Timer:
When the motor is active, pressing this key will activate the timer for motor shut-down after
15 minutes. At the end of the 15' the motor and the light will switch off and the mobile part will
close. The red LED flashes to indicate that the function is active. The countdown does not stop
(exhaust)