Turning Off - Bertos GL18 Serie Manual De Instrucciones

Tabla de contenido
Igniting the pilot burner (GL7+7, GL15..., GL20...,
GL22...) (fig.8)
Press down the knob and rotate it anticlockwise to the (
) (PILOT) position.
In this position, keep the knob pressed down while
pushing the piezoelectric button several time until the
pilot flame ignites. For the models 9GL20.... 9GL22...,
S9GL20..., S9GL22..., turn the knob to activate the
piezoelectric button (see fig. 10).
Release the knob after 5 seconds and turn it to the desired
position. Repeat the same operation if the pilot flame goes out.
Pilot burner ignition (GL18..., SGL18..., 9GL18..., S9GL18...,
LX9GL18..., 9GL22...EL, S9GL22...EL, LX9GL22...EL) (fig. 8)
Rotate the knob (1) anticlockwise up to the position (
In this position, press the knob until the pilot flame lights
up. Release the knob after 60 seconds and rotate it to the
position . Repeat the operation if the pilot flame goes out.
Switching on the pilot burner (F and FA models - fig. 14)
Press the "D" button and the green "C" light will light up to
show the presence of voltage.
Rotate the knob "G" anticlockwise up to the position (
In this position, press the knob until the pilot flame lights
up. Release the knob after 60 seconds and rotate it to the
position . Repeat the operation if the pilot flame goes out.
Main burner Ignition and temperature regulation
(GL8..., GL10..., GL7+7, GL15..., GL20..., GL22...)
To turn on the main burner, rotate the knob further
anticlockwise up to the desired temperature. The
thermostat valve is marked in positions from 1 to 8 for the
600 Series and from 1 to 7 for the 700/900 Series.
The values indicating the temperature in each position are
the following:
8 position valve
Position
0
1
Temperature °C
Off
110 121 133 145 156 168 179 190
7 position valve
Position
0
1
Temperature °C
Off
115 130 143 157 171 180 190
Main burner Ignition and temperature regulation
(GL18...MI,
SGL18...MI,
LX9GL18...MI, 9GL20...EL, 9GL22...EL, S9GL22...EL,
LXGL22...EL, S9GL20...FA)
To switch the main burners, rotate the thermostat knob on
the panel up to the desired temperature value.

TURNING OFF

Turning off during normal operation
Turning off (GL8..., GL10...) (fig. 7)
To turn off the main burners, rotate the knob (1) to the
position (
); in this position only, the pilot flame is
switched on. To turn off the appliance completely, press
the off button (
) (4).
Before switching on again, wait for about 1 minute so that
the valve releases.
2
3
4
5
6
7
8
2
3
4
5
6
7
9GL18...MI,
S9GL18...MI,
Turning off (GL7+7, GL15..., GL20..., GL22...) (fig. 8)
To turn off the main burners, rotate the knob (1) to the
position (
) ; in this position, only the pilot flame is
switched on. To turn off the appliance completely, rotate the
knob up to the position (
Turning off (GL18..., SGL18..., 9GL18..., S9GL18...,
LX9GL18..., 9GL22...EL, S9GL22...EL, LX9GL22...EL) (fig. 8)
To turn off the main burners, rotate the thermostat knob
on the panel up to zero; rotate the knob (1) up to the
position (
); in this position, only the pilot flame is
switched on. To completely turn off the appliance, rotate
the knob (1) up to the position (
).
Models (9GL20..., 9GL22..., S9GL20..., S9GL22...) (fig. 10)
To turn off the main burners, turn the knob to . To turn off
the pilot light, turn the knob to
Switching off (F and FA models - Fig. 14)
To turn off the main burners, rotate the thermostat knob
on the panel up to zero; rotate the knob (B) up to the
position (
); in this position, only the pilot flame is
).
switched on. To switch off the unit completely, rotate the
(G) knob to the (
) position and press the "D" button; the
green "C" light will switch off.
Turning off in the event of a failure
In the event of a failure, cut off the gas supply to the
appliance.
What to do in case of malfunctioning or if the appliance
is not used for a long period of time
If the appliance is not to be used for a long period of time,
or in the event of a failure or malfunctioning, turn off the
external gas supply tap connecting to the main line. After
performing all cleaning operations, the stainless steel
surfaces should be well dried and protected with standard
anti-corrosion products. In the event of a failure, call
Technical Assistance.
F AND FA MODELS OPERATION
Use the automatic basket lifter, set the cooking time
(FA models - Fig. 14)
The basket lifter can be used either with 1 basket or 2 half
baskets.
To use the basket lifter with 2 half baskets, set the fryer
compartment's "M" switch to the "2 baskets" position.
To use the basket lifter with 1 basket, set the "M" switch
to the 1 basket position. In this case, set the fry time by
rotating the right "A" knob. The left "A" knob is not enabled.
Set the frying time by rotating the "A" knob to the value
you want.
As soon as the "A" knob is rotated, the basket will lower.
When the set time is reached, the cooking cycle finishes
and the basket lifts up.
Oil filtering and use of the pump (F and FA models - Fig.
14)
Make sure that the "G" knob of the valve in in the "
position. Make sure that the tray and the filter are
positioned under the oil drain.
| 107
).
).
.
EN
"
Tabla de contenido
loading

Tabla de contenido