Such containers or tanks must be rinsed before welding
to remove flammable liquids. Do not weld in the vicinity
of flammable gas, vapours or liquids. Fire equipment
(blankets, dry powder extinguisher or extinguishing foam)
must be placed near the workplace in an easily visible and
reachable place.
A CYLINDER MAY EXPLODE
Use only approved gas cylinders and a properly working
reducer. The cylinder should be transported, stored and
placed in a vertical position. Protect the cylinders from heat
sources, tipping over and mechanical damage. Maintain all
gas installation elements: cylinder, hose, fittings, reducer in
good condition.
WELDED MATERIALS CAN CAUSE BURNS
Never touch the welded components with parts of your
body without protection. When touching and moving
welded material, always use welding gloves and tongs.
3.3. PREPARATION OF WELDING WORK SITE
WELDING
OPERATIONS
MAY
CAUSE
FIRE
EXPLOSION!
Strictly follow the occupational health and safety
regulations applicable to welding operations and
make sure to provide appropriate fire extinguishers
at the welding work site.
Never carry out welding operations in flammable
places that pose the risk of material ignition.
It is prohibited to weld in the presence of an
explosive mixture of combustible gases, vapours,
mists or dust with air.
Remove all flammable materials within 12 meters
from the welding operations site and if removal is
not possible, cover flammable materials with fire
retardant covering.
Use safety measures against sparks and glowing
metal particles.
Make sure that sparks or hot metal splinters do
not penetrate through the slots or openings in the
coverings, shields or protective screens.
Do not weld tanks or barrels that contain or have
contained flammable substances. Do not weld in the
vicinity of such containers and barrels.
Do not weld pressure vessels, pipes of pressurised
installations or pressure trays.
Always ensure adequate ventilation.
It is recommended to take a stable position prior to
welding.
3.4. PERSONAL PROTECTION EQUIPMENT
ELECTRIC ARC RADIATION CAN CAUSE DAMAGE TO
EYES AND SKIN!
When welding, wear clean, oil stain free protective
clothing made of non-flammable and nonconductive
materials (leather, thick cotton), leather gloves, high
boots and protective hood.
Before welding remove all flammable or explosive
items, such as propane butane lighters or matches.
Use facial protection (helmet or shield) and eye
protection, with a filter featuring a shade level
matching the sight of the welder and the welding
current. The safety standards suggest colouring
No. 9 (minimum No. 8) for each current below 300
A. A lower shield colouring can be used if the arc is
covered by the workpiece.
Always use approved safety glasses with side
protection under the helmet or any other cover.
EN
Use guards for the welding operation sites
in order to protect other people from the
blinding
light
radiation
or
projections.
Always wear earplugs or another hearing protection
to protect against excessive noise and to avoid
spatter entering the ears.
Bystanders should be warned to not look at the arc.
3.5. PROTECTION AGAINST ELECTRIC SHOCK
ELECTRIC SHOCK CAN BE LETHAL!
The power cable must be connected to the nearest
socket and placed in a practical and secure position.
Positioning the cable negligently in the room and on
a surface which was not checked must be avoided, as
it can lead to electrocution or fire.
Touching electrically charged elements can cause
electrocution or serious burns.
The electrical arc and the working area are electrically
charged during the power flow.
The device's input circuit and inner power circuit are
also under voltage charge when the power supply
OR
is turned on.
The elements under the voltage charge must not be
touched.
Dry, insulated gloves without any holes and
protective clothing must be worn at all times.
Insulation mats or other insulation layers, big enough
as not to allow for body contact with an object or the
floor, must be placed on the floor.
The electrical arc must not be touched.
Electrical power must be shut down prior to cleaning
or electrode replacement.
It must be checked if the earthing cable is properly
connected or the pin is correctly connected to the
earthed socket. Incorrectly connecting the earthing
can cause life or health hazard.
The power cables must be regularly checked for
damage or lack of insulation. Damaged cables must
be replaced. Negligent insulation repair can cause
death or serious injury.
The device must be turned off when it is not in use.
The cable mustn't be wrapped around the body.
A welded object must be properly grounded.
Only equipment in good condition can be used.
Damaged device elements must be repaired or
replaced. Safety belts must be used when working
at height.
All fittings and safety elements must be stored in
one place.
From the moment of turning on the release, the
handle end must be kept away from the body.
The chassis ground must be mounted to the welded
element or as close to it as possible (e.g. to a work
table).
THE DEVICE CAN STILL BE UNDER VOLTAGE UPON
FEEDER DISCONNECTION!
The voltage in the input capacitor must be checked
upon turning off the device and disconnecting it
from the power source. One must make sure that the
voltage value is equal to zero. Otherwise, the device
elements must not be touched.
3.6. GASES AND FUMES
PLEASE NOTE! GAS MAY BE LETHAL OR DANGEROUS
TO HUMAN HEALTH!
Always keep a certain distance from the gas outlet
When welding, ensure good ventilation. Avoid
inhaling the gas.
10
Chemical substances (lubricants, solvents) must be
removed from the surfaces of welded objects as they
burn and emit toxic smokes under the influence of
temperature.
The welding of galvanised objects is permitted only
when efficient ventilation is provided with filtration
and access to fresh air. Zinc fumes are very toxic, an
intoxication symptom is the so-called zinc fever.
4. OPERATION
4.1. GENERAL NOTES
The device must be applied according to its purpose,
with observance of OHS regulations and restrictions
resulting from data included in the rating plate (IP
level, operation cycle, supply voltage, etc.).
The machine must not be opened as it will cause
warranty loss and, in addition, exploding. Unshielded
elements can cause serious injuries.
The producer does not bear any responsibility for
technical changes in the device or material losses
caused by the introduction of the said changes.
In case of incorrect device operation, contact the
service centre.
Louvers must not be shielded – the welder must
be positioned at 30 cm distance from the objects
surrounding it.
The welder must not be kept under your arm or near
your body.
The machine must not be installed in rooms with
aggressive environments, high dustiness and near
devices with high electromagnetic field emission.
4.2. DEVICE STORAGE
The machine must be protected against water and
moisture.
The welder must not be positioned on heated
surfaces.
The device must be stored in a dry and clean room.
4.3 CONNECTING THE DEVICE
4.3.1 CONNECTING THE POWER
The connection of the device must be performer by
a qualified person. In addition, a person with required
qualifications should check if the earthing or electrical
installation with protection system is in line with the
safety regulations and if they operate correctly.
The device must be placed near the work station.
Connecting excessively long conduits to the machine
must be avoided.
One-phase welders should be connected to the
socket fitted with an earthing prong.
Welders powered from a 3-Phase network are
delivered without a plug, the plug must be obtained
independently and installation should be assigned to
a qualified person.
PLEASE NOTE! THE DEVICE MAY ONLY BE USED UPON
CONNECTION TO AN INSTALLMENT WITH A PROPERLY
FUNCTIONING FUSE.
4.3.2 CONNECTING GAS
Gas tanks must be placed far from the welded object
and be protected against falling.
Gas connector of the welder must be connected with
the tank or gas installation by means of the correct
pipe and regulator with gas flow regulation. Please
note! Connection of line regulators to the tank and
the other way round is prohibited. Such a change can
result in regulator damage and serious injuries.
Economical gas use extends the welding time.
EN
5. DEVICE USE
2
1
3
11
4
10
9
5
6
7
8
No.
Function and description
1.
ERROR INDICATOR = The indicator lights in the
following two situations:
a) If the machine has malfunctioned and cannot
be operated.
b) If the cutting device has exceeded the
standard working time the protection mode is
initiated and the machine will stop functioning.
This means that the machine is now being cooled
in order to be able to restore temperature control
again after the device has overheated. Therefore
the machine is stopped. During this process, the
red warning light on the front panel lights up. In
this case it is not necessary to remove the power
plug from the socket. The ventilation system
may be left on in order to enhance the cooling
of the machine. When the red light goes dark,
this means that the temperature is now down to
the normal level and the unit can be put back
into operation.
2.
Power on indicator
3.
POSTFLOW TIME – Gas time flow post welding
adjustment knob 1~15s.
4.
DOWNSLOPE – Downslope welding current
adjustment 1~10s.
5.
Return lead socket
6.
Welding lead socket.
7.
Welding torch control socket
8.
TIG gas socket
9.
2T/4T SWITCH:
2T – press this button on the burner to start the
metal welding process, release this button to end
this process.
4T – press this button on the burner to start the
metal welding process, releasing this button
does not end this process. Press and release this
button again to end the metal welding process.
10.
TIG / MMA mode switch
11.
Welding current adjustment knob
11