manuale_SALAD_BAR_LINE_MUSIC_GB.qxp
1 1 3 3 . . 1 1 0 0 A A l l a a r r m m m m a a n n a a g g e e m m e e n n t t p p a a r r a a m m e e t t e e r r s s
N N ° ° C C o o d d . P P a a r r a a m m e e t t e e r r
A0
61
62
A1
63
AL
AH
64
65
Ad
66
A4
67
A5
68
A6
A7
69
70
A8 Enable alarms 'Ed1'and 'Ed2'
Ado
71
Ac
72
73
AE
74
Acd
75
AF
76
ALF
77
Adf
A A L L : : M M i i n n i i m m u u m m t t e e m m p p e e r r a a t t u u r r e e a a l l a a r r m m
This is used to determine the activation threshold for the low temperature alarm. Relative thres-
hold for low temperature alarm = (set point) - (value of 'AL')
Absolute threshold for low temperature alarm = value of AL.
I I m m p p o o r r t t a a n n t t : : If the threshold AL is selected as relative, the value for disabling the alarm is 0, while
if selected as absolute, the alarm disabling value is -50.
W W a a r r n n i i n n g g s s f f o o r r t t h h e e r r e e l l a a t t i i v v e e t t h h r r e e s s h h o o l l d d : :
• the value of AL does not indicate the alarm temperature, but the maximum permissible devia-
tion off the set point; changing the set point automatically
changes the low temperature alarm, while the maximum deviation allowed (=AL ) remains fixed;
W W a a r r n n i i n n g g s s f f o o r r u u s s i i n n g g t t h h e e c c o o n n t t i i n n u u o o u u s s c c y y c c l l e e : :
• the low temperature alarm is also used in the continuous cycle (see the description of para-
meter 'cc'). In fact, if the temperature falls to the alarm level, the continuous cycle is stopped
automatically, even if the selected time has not yet elapsed.
Code CT55900010
13/07/2006
Alarm and fan differential
Type of threshold' AL' and
'AH'
Low temperature alarm
threshold
Hight temperature alarm
threshold
Low and hight temperature
signal delay
Digital input 1 configuration
Digital input 2 configuration
Stop compressor from
external alarm
External alarm detection
delay
Light management mode
with door switch
Hight condenser temperature
alarm
Hight condenser temperature
alarm differential
Hight condenser temperature
alarm delay
Light sensor OFF time
Antifreezer alarm threshold
Antifreezer alarm delay
English - 36
11.11
Pagina 36
U U . . M M .
T T y y p p e e D D e e f f .
M M S S Y Y R R
c
MSYF
°C/°F
c
MSYF
flag
f
°C/°F
MSYF
°C/°F
c
MSYF
MSYF
min
c
-
-SYF
c
-
c
M---
-
MSYF
c
-SYF
min
c
-SYF
min
c
-SYF
flag
c
c
MSYF
flag
-SYF
°C/°F
c
-SYF
°C/°F
c
-SYF
min
c
-SYF
c
sec
MSYF
°C/°F
c
MSYF
min
c
M M a a x x M M i i n n .
2.0
20
0.1
0
1
0
0.0
-50
200
0.0
200
-50
120
250
0
0
14
0
0
14
0
0
14
0
0
100
0
0
250
0
0
1
0
0
0
1
70.0
200
0.0
5.0
20
0.1
0
250
0
0
250
0
-5.0
200
-50
1
15
0
Rev. 03 - 07/'06