Technical data flow sensor model IMF
Nominal flow
Nominal diameter
Overall length without
connectors
Length with connectors
approx.
Thread meter G x B
Thread connector R x
Metrological class
Installation position
Pulse value
Cable length
Maximum flow
Minimum flow *
Temperature range
Nominal pressure
Ambient conditions /
climatic influencing
Pressure loss at q
p
Heat carrier
Height
Width
Weight
* optionally
q
m³/h
3.5
p
DN
mm
25
inch
1
L2
mm
260
L1
mm
378
D1
inch
1 ¼
D2
inch
1
l/pulse
10
m
q
m³/h
7
s
q
m³/h
0.14
i
°C
PN/PS
bar
- climatic
- metrological
class
- elektromagnetic
class
bar
H1
mm
160
H2
mm
40
B
mm
95
kg
2.9
Dimensions IMF
3.5
6
6
25
25
25
--
1
--
260
260
260
--
378
--
Flange
1 ¼
Flange
--
1
--
Standard class 2, optionally 3 according to EN 1434
horizontal (the register always has to face upwards)
10
10
10
1,5 / 3 (it will be extendable by 7 m)
12
12
12
0.12
0.12
0.12
0.24
0.24
0.24
5° C ≤ Θq ≤ 120 °C
16 (Threaded connection) / 25 (Flange)
Highest permissible ambient temperature 55 °C
Lowest permissible ambient temperature 5 °C
Protection class IP65
M2
E2
≤ 0,25
Water
glycol (without Declaration of conformity)
160
160
160
40
40
40
95
95
95
4.5
2.9
4.5
6
6
10
32
32
40
1 ¼
--
1 ½
260
260
300
384
--
428
1 ½
Flange
2
Flange
1 ¼
--
1 ½
10
10
10
12
12
20
0.12
0.12
0.2
0.24
0.24
0.4
160
160
174
40
40
50
95
95
110
2.9
5.8
5.1
10
40
--
300
--
--
10
20
0.2
0.4
174
50
110
9.5
9
Tabla de contenido