2 609 932 523.book Seite 1 Dienstag, 25. April 2006 3:25 15
Unit Specifications
Battery Charger
Order number
Output voltage
[V=]
Charging current
[A]
Allowable charging
temperature range
[°C]
Charging time per
battery capacity,
approx.
1.3 Ah
[min]
Weight according
to EPTA-Procedure
01/2003
[kg]
Protection class
Unit Elements
The numbering of the unit elements refers to the
representation of the unit on the graphic page.
Please open the fold-out page with the represen-
tation of the unit and leave it open while you are
reading the operating instructions.
1 Battery*
2 Charging compartment
3 Red charge control LED
4 Green charge control LED
* Not all of the accessories illustrated or described are
included as standard delivery.
For Your Safety
Read all instructions. Failure to
follow all instructions listed below
may result in electric shock, fire
and/or serious injury.
SAVE THESE INSTRUCTIONS.
Protect the battery charger from rain and
moisture. The penetration of water in a bat-
tery charger increases the risk of electric
shock.
Do not charge other batteries. The battery
charger is suitable only for charging Berner
lithium ion batteries within the listed voltage
range. Otherwise there is danger fire and ex-
plosion.
Keep the battery charger clean. Contamina-
tion may cause the danger of electric shock.
Check the battery charger, cable and plug
BACC 10,8 V LI
each time before using. Do not use the bat-
034298
tery charger when defects are detected. Do
10.8
not open the battery charger yourself and
3.0
have it repaired only by qualified personnel
using original spare parts. Damaged battery
0 – 45
chargers, cables and plugs increase the risk of
electric shock.
Do not operate the battery charger on eas-
ily inflammable surfaces (e. g. paper, tex-
30
tiles, etc.) or in combustible environments.
There is danger of fire due to the heating of the
battery charger during charging.
0.5
/ II
Starting Operation
Observe correct mains voltage: The voltage of
the power source must agree with the voltage
specified on the nameplate of the unit. Equipment
marked with 230 V can also be connected to
220 V.
Charging Procedure
The charging procedure starts as soon as the
mains plug is plugged into the socket and the bat-
tery 1 is inserted into the charging compart-
ment 2 .
Due to the intelligent charging method, the charg-
ing condition of the battery is automatically de-
tected and the battery is charged with the opti-
mum charging current, depending on battery
temperature and voltage.
This gives longer life to the battery and always
leaves it fully charged when kept in the charger
for storage.
Meaning of the
Indication Elements
Control of the charging procedure is indicated via
the charge control LEDs 3 and 4 :
Rapid-charging Procedure
English - 1
The rapid-charging procedure is in-
dicated by flashing of the green
charge control LED 4 .
The rapid-charging procedure is possible
only when the temperature of the battery is
between 0 °C and 45 °C.