1.0 PARTS SUPPLIED

e-MOTE infrared wall-mounted washbasin
mixer ON-OFF function,
exposed trim parts:
Projection 150 mm
36.730.850.FF
Projection 170 mm
36.731.850.FF
Infrared wall-mounted washbasin mixer
concealed rough parts: wall housing in wall
installation box
35.730.970.90
Exposed trim parts:
• Covering rosette complete with
- Infrared sensor
- Flow reducer, 5 l/min
- Aerator, M 16 x 1
- 6 Volt lithium battery
• Mounting frame
• Set of fixtures
concealed rough parts:
• Wall housing in wall installation box with
- Solenoid valve
- Mixer
- 2 supply stops
- 2 back flow preventers with dirt trap
- 2 connections, G 1/2
- High pressure connector hose
• Set of fixtures
• Set of drain fittings

2.0 OPERATING CONDITIONS

Recommended feed temperature
Maximum feed temperature (temporary)
Minimum flow pressure
Maximum flow pressure
Recommended operating pressure
Test pressure
Noise class
Flow rate
approx. 5 l/min
Battery
Lithium 6 V, 2 CR 5
Battery life
Approx. 5 years
when used 200 times a day
1
Reception range:
100 - 30 mm
Safety shutoff
Enclosure rating
Mark of conformity
2
At an idle pressure of more than 5 bar, the insta-
llation of a pressure reducer to DIN 1988 in the
supply line is recommended.
The fittings are not suitable for use in conjunction
with pressureless storage water heaters.
Observe DIN 1988 in the case of newly installed
pipe systems.
No problems are expected with performance when
used in conjunction with electronic continuous-flow
water heaters.
When used in conjunction with hydraulic conti-
nuous-flow water heaters which switch on at a flow
rate < 4l/min, the volume control in the inset spout
nipple must be removed.
3.0 FUNCTION
ON/OFF function
When the hands are placed within approx.
100-30 mm of the infrared sensor, the mixer is
switched on. The mixer cuts out again if the hands
are moved within the infrared sensor's range a
second time. If the hands are not moved towards
the sensor a second time, the mixer automatically
cuts out after 1 min.
Temperature adjustment:
The water temperature can be adjusted by turning
the mixer knob 2.
Battery display
If the LED in the upper sensor lens 1 flashes, the
mixer is no longer operational.
The lithium battery 15 must be changed.
See 5.0 CHANGING THE BATTERY.
65° C
80° C
4.0 INSTALLATION
1 bar
Concealed rough parts
10 bar
Installed height 150-200 mm above washbasin
1-5 bar
upper edge.
16 bar
I / ISO 3822
Align wall housing horizontally with wall installation
box and secure with the enclosed fastening
materials. Installed position see
Connect up pipes:
Cold-water connection (KW) = right (blue)
After 1 min
Hot-water connection (WW) = left (red)
IP 45
Insert the enclosed drain plug in the place of the
back-flow preventer (RV).
Rinse the pipes.
Then insert the back-flow preventer (RV) again.
Open the supply stop.
Fit the bare brickwork protective hood.
The distance between the tiles and the wall
installation box may be no more than 5 mm.
Fig. 4
Fig. 3
Fig. 3
OFFEN
OPEN
CLOSED
Fig. 5
OPEN
Figs. 1 + 2
Fig. 4
Fig. 5
Fig. 5
Fig. 6
Fig. 6
3
RV
ZU
GB
CLOSED
4
Tabla de contenido
loading

Este manual también es adecuado para:

36 730 85036 731 850

Tabla de contenido