86
AVENTICS | DeviceNet | R402003659–BAL–001–AG
Appendix – Bus master configuration
Max. Instance
13.3.6
Discrete Output Point (Class 0x09)
Table 23
Class and Instance Attributes – Discrete Output Point
Object
Object
Class
Instance
0x09
0x00
0x09
0x01 + i
Table 24
Common Services – Discrete Output Point
Service Code
0x0E
0x10
The value of the "Max. Instance" attribute represents the number of
output points. The value is always a multiple of 8 (n x 8 points). The bus
coupler has 32 bit valve outputs.
Max. Instance = 0x20 (hex)
13.4
Manufacturer specific objects
13.4.1
I/O Data Object (Class 0x64)
Table 25
Class and Instance Attributes – I/O Data Object
Object
Object
Class
Instance
0x64
0x00
0x64
0x01
Object
Object description
Attribute
0x01
Revision
of the DeviceNet Object
0x02
Max Instance
Maximum number of instances for this
object
0x03
Output Point Value
Output data as individual bits
i = 0...n output data bits
Service Name
Get Attribute Single
Set Attribute Single
Object
Object description
Attribute
1
Revision
of the I/O Data Object
2
Max Instance
Maximum number of instances for
I/O Data Object
0x64
Number of Inputs
Number of input bytes
0x65
Number of Outputs
Number of output bytes
0x67
Output Data
Output data as an entire stream