AVENTICS | DeviceNet | R402003659–BAL–001–AG
If Malfunctions Occur
General data
Dimensions
Weight
Operating temperature range
Storage temperature range
Protection to EN 60529/IEC529
Compressed air quality
Working pressure
Nominal flow
Mounting orientation
Electrical data
Operating voltage
W
Electronics
–U
L
–I
L
W
Load U
, U
Q1
Q2
Fuse protection for valve power supply
Fuse protection for electronics supply
Line length for power supply
Current in 0 V line
Internal voltage drop
Output current per valve output
No. of outputs
No. of output bytes
Start-up time
10 If Malfunctions Occur
In case of malfunction, refer to "Test and diagnosis" on page 73 for
troubleshooting. Refer to "Replacement" on page 74 for information on
how to replace a faulty bus coupler.
11 Technical Data
Depend on configuration; see online catalogue.
Depend on configuration; see online catalogue.
0 °C to +50 °C, without condensation
–20 °C to +70 °C
When assembled: IP 69K
To DIN ISO 8573-1, class 6, 4, 3 or lower
solid pollutants: ≤ 5 μm
dew point: ≤ 3 °C
oil content: ≤ 1 mg/m
2.5 - 10 bar
950 - 1100 std. l/min, depending on valve type and subbase at 6 bar
pilot pressure, Δ = 1 bar
Any
24 V DC (+20%/-15%)
50 mA
24 V DC (10%/15%)
2 x 3.0 A (F)
500 mA (F)
Max. 20 m
Max. 4 A
0.6 V
Max. 100 mA
Max. 32
Fixed, output 4 bytes and input 0 bytes
Approx. 1 s
The corresponding declaration of conformity is included on CD
R412023902.