viously displayed start current.
Range 0.1-10 sec., manufacturer setting 0.7.
Changed using keys O and R.
-Slo (Slope)
Range 0.1-10 sec., manufacturer setting 0.5.
Changed using keys O and R.
Defines the interface time between the first current
(SC) and the welding current set using knob B in the
welding programs.
How it works in practice:
Welding takes place in manual mode (two stages).
The operator begins welding with the current corre-
sponding to the percentage greater than or less than
the wire speed set in SC (in this specific instance,
30% higher). This current will have a duration, in sec-
onds, corresponding to the time set in Len (in this
specific instance, 0.7 sec), after which the current will
drop to the current set using knob B (welding) in the
time set with Slo (in this specific instance, 0.5 sec).
We recommended this function for spot welding
sheet aluminium.
If this function is not activated, pressing the torch trigger
activates the function:
• 3L (three levels)
Active in pulsed synergic curves
Caution: If the function 3L is activated, the function
HSA is automatically not included.
Display Q shows the message OF =OFF = Off
Pressing the key O causes the display Q to show the
message On = Active.
If this function is activated, pressing the torch trigger
causes the following messages to appear in sequence.
-SC (Start current)
Range 1-20 (10-200%) of the wire speed correspond-
ing to the welding current set using knob B in the
welding programs. Manufacturer setting 13 (130%).
Changed using keys O and R.
-Slo (Slope)
Range 0.1-10 sec., manufacturer setting 0.5.
Changed using keys O and R.
Defines the interface time between the first current
(SC) and the welding current set using the knob B in
the welding programs, and between the welding cur-
rent and the third "crater filler" current CrC.
-CrC "Crater filler" current
Range 1-20 (10-200%) of the wire speed correspond-
ing to the welding current set using knob B in the
welding programs. Manufacturer setting 6 (60%).
Changed using keys O and R.
How it works in practice:
Welding takes place in automatic mode, thus the exe-
cution times are decided by the operator.
Especially recommended for MIG welding of aluminium.
Three currents are available, which may be called up
during welding using the torch start button.
Welding begins when the torch button is pressed. The
welding current used will be the one set using the SC
function (in this specific instance 13 =130%). This
current will be kept for as long as the torch trigger is
held down; when released, the first current changes
to the welding current, set with the knob B, within the
time established by the Slo function (in this specific
instance, 0.5 sec.), and will be kept until the torch
14
trigger is pressed again. The next time the torch trig-
ger is pressed, the welding current will switch to the
third or "crater-filler" current, set with the function
CrC (in this specific instance, 6 = 60%), in the time
established by the function Slo (in this specific
instance, 0.5 sec), and will be maintained as long as
the torch trigger is held down. Welding stops when
the trigger is released.
If this function is not activated, pressing the torch trigger
activates the next function.
• PrF (Pre-gas)
Active in all welding programs.
Range 0.0 - 9.9 sec. Setting 0.1 sec. Changed using keys
O and R.
• PoF (post-gas)
Active in all welding programs.
Range 0.1 - 9.9 sec. Setting 3.0 sec. Changed using keys
O and R.
• Acc (Soft Start)
Active only in pulsed synergic welding programs .
Range Auto - 1-99%. This is the wire speed, expressed
as a percentage of the speed set for the welding, before
the wire touches the workpiece.
Note: This adjustment is important in order to always
achieve good starts.
Manufacturer setting "Au" automatic.
Changed using keys O and R. If, after changing, you wish
to return to the manufacturer setting, press keys O and R
simultaneously until the abbreviation "Au" appears on
display Q.
• bb (Burn-back)
Active in all welding programs.
Range 00 - 99. Manufacturer setting "Au" automatic.
Serves to adjust the length of the wire leaving the gas
nozzle after welding. The higher the number, the more the
wire burns.
• PPF (Push Pull Force)
Adjusts the drive torque of the push-pull torch motor.
Serves to make the wire advance in a linear fashion.
Range 9/-9, manufacturer setting 0.
Changed using keys O and R.
• dP (double pulse)
This type of welding varies the current intensity between
two levels wire speed, so as to obtain a more constant
penetration and an appearance of the bead similar to
what is obtained with TIG welding.
Default = OF = OFF = Off
Adjustments:
On = The welding machine performs the adjustments
that the operator sets (manual mode).
Au = The welding machine makes the adjustments that
the manufacturer has set; if these adjustments are
altered, the welding machine passes into "manual
mode", thus in On .
NOTE: To quickly start this type of welding, read the
description of the O Key.