Diagnóstico Inicial Del Sparc M12-2S Que Se Va A Añadir - Fujitsu SPARC M12-2S Guia De Instalacion

Tabla de contenido
Do you want to start to diagnose BB#1?[s:start|c:cancel] : c
Diagnostic tests are about to be skipped.
Running diagnostic tests are strongly recommended before using
BB#1.
Are you sure you want to skip testing?[y:yes|n:no] : y
[Warning:007]
Running diagnostic tests on BB#1 is strongly recommended
after addfru has completed.
The addition of BB#1 has finished.[f:finish] : f
------------------------------------------------------------------------------
Maintenance/Addition Menu
Please select the chassis including added FRU.
No. FRU
--- ------------------- --------------
1
/BB#0
2
/BB#1
3
/BB#2
4
/BB#3
------------------------------------------------------------------------------
Select [1-4|c:cancel] : c
8.5
Diagnóstico inicial del SPARC M12-2S
que se va a añadir
Aquí se realiza un diagnóstico inicial del SPARC M12-2S añadido.
Nota - Para la expansión de sistema detenido, realice el procedimiento que se describe en
Realización de una prueba
1.
Ejecute el comando testsb para realizar un diagnóstico del hardware.
Para XX-Y, especifique el número PSB del diagnóstico inicial. XX=BB-ID y Y=0
son configuraciones fijas.
Se realiza un diagnóstico inicial de la PSB destino de diagnóstico y una
confirmación de las E/S conectadas.
<Descripción de las opciones especificadas>
-v: Muestra el mensaje detallado del diagnóstico del hardware.
-p: Muestra el almacenamiento conectado al SPARC M12-2S.
-s: Muestra el árbol de dispositivos.
-y: Responde automáticamente con "y".
Guía de instalación de Fujitsu SPARC M12-2S ・ Julio de 2018
240
Status
Normal
Normal
Unmount
Unmount
diagnóstica", no este procedimiento.