Programming Procedure; Remote Control - Cardin Elettronica PRG303 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Check that the activation of the safety devices (those that have not been bridged) switch
the corresponding LEDS off.
If the green power on LED doesn't light up check the condition of the fuses "F1" and "F2"
and the power cable connection between binding posts "3" and "4" (fig. 1).
If one or more of the safety LEDS do not light up, check the contacts of the relative security
devices and check that the unused safety device contacts have been bridged.

PROGRAMMING PROCEDURE

To start programming the shutter must be completely closed.
- Keep the button "P1" (fig. 1) pressed down for about 5 seconds. The red led "LD2" will
light up meaning you have entered programming.
- Release the button (holding it down will have no other effect)
Note: in this stage the programming button is the only enabled command.
- Pressing the button a second time will force an opening cycle to begin and the work
cycle count to start; this only occurs during the opening stage. If an object interrupts the
photocells, movement will stop and the work cycle will be put on hold until the obstacle
has been removed, at which point the cycle will continue as before.
The "blocked status" is determined by:
- the intervention of an opening direction travel limit; the work cycle count carries on but
all movement is halted.
- pressing the button "P1"; the work cycle count is halted and the pause time count is
started.
- pressing the button "P1" a second time will end the work time count and start the pause
time which is indicated by the indicator lamp lighting up at one-second intervals.
- pressing the button "P1" a third time will memorise the parameters under EEPROM and
exits programming: these parameters are verified straight away and if everything is cor-
rect the Led "LD2" will switch off and the shutter will move in the closing direction.
- If the parameters have not been correctly memorised under EEPROM the led will flash
until you start the programming procedure again.
Attention! the led "LD2" will continue to flash if an object is interrupting the photocells when
"P1" is pressed for the third time. Once you have removed the object, the led will switch off
and the shutter will move in the closing direction.
The warning lights work normally during the programming period and are therefore active
while the shutter is moving.

REMOTE CONTROL

The dynamic command can be also be controlled via radio by inserting a Cardin standard
radio receiver card into the "R1" (fig. 1) interface slot. It is possible to manage a single chan-
nel associated with the dynamic function. For ulterior information consult the instruction
manual supplied with the receiver card.
11