18
I-17 / I-40 Manual and Spark Ignition
FIG. 12
WATER HOSE
2. Repeat steps until water runs clean.
3. Inspect the cones and venturi tube to make
sure these areas are clean.
4. Shake the heater vigorously to clear water off
of the combustion cones to allow proper igni-
tion of gas at the inner cone.
5. Return the heater to its original hanging
position.
6. Relight the heater to dry out the cones and the
venturi tube.
C. FILTER (Accessory): Manual and Spark
Ignition Heaters
A. During continued use:
- Remove filter and shake off dust.
- Do not squeeze or tap filter while filter is in-
stalled on heater. Doing so will cause dust to be
blown into venturi tube or combustion cones.
B. After continued use or before building
repopulation:
- Remove filter and shake off dust.
- Use compressed air or water (standard faucet
pressure) to clean it.
- Do not use high pressure water, air, or a wash-
ing machine. Filter material damage may occur.
- If water is used, squeeze out excess water from
filter before installation.
- Let filter air dry before lighting heater.
Owner's Manual • I-17 / I-40