In-Place Sanitization; Routine Maintenance - Bras B-Cream Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

rear wall (see figure 10).
figure 10
5 Reassemble the hexagonal joint and then the mixer (see
figure 11).
figure 11
6 Replace the container by pushing it towards the back wall,
making sure it fits properly onto the gasket. The locking lever
will be lowered until it rests on the drip tray surface (see figure
12).
7 Rinse using a cool beverage in order to eliminate any
remaining sanitising solution from the bottom of the containers.
Dry the inside of the containers with a disposable paper towel.

5. 4 IN-PLACE SANITIZATION

Sanitising the assembled device, prior to putting into
service, should only be performed, if necessary, as an
a d d i t i o n a l p r e c a u t i o n t o t h e s a n i t i s a t i o n o f t h e
disassembled devices described previously, never instead
of it.
1 Prepare a solution of water and sanitising product approved
by the authorities in your country in a basin, according to the
manufacturer's specifications. In the absence of a specific
sanitising product, prepare a solution of water and sodium
hypochlorite (bleach) at a ratio of 1 tablespoon per 2 litres of
water.
2 Pour the solution into the containers.
3 Using a suitable brush, wipe the solution onto all parts
above the level of the solution and on the underside of the lid.
4 Install the lid and operate the dispenser in order to allow the
solution to be stirred for about 2 minutes. Drain the sanitising
solution from the containers through the taps and then dispose
of it.
5 Rinse using a cool beverage in order to eliminate any
remaining sanitising solution from the bottom of the containers.
Do not perform further rinsing.

6 ROUTINE MAINTENANCE

1 Every day: inspect the dispenser and check for leaks of
product from the gaskets. If you notice leaks, first make sure
that the components of the dispenser are properly installed,
then check that the gaskets do not require lubrication and
finally that they are not worn or damaged. If they are, replace
them with original spare parts from the manufacturer.
ATTENTION
Before any cleaning operation, always unplug the
dispenser from the mains.
2 Every month: check that the hexagonal joint gasket is not
worn. If it is, replace the joint itself with an original spare part
17
figure 12
Tabla de contenido
loading

Tabla de contenido