5- Wiring; Connect The Cable - Saunier Duval 3-035 AK Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1

5- WIRING

CAUTION!
The air conditioner should use separate power
supply with rated voltage.
The wiring work should be done by qualified
persons according to circuit drawing.
An all-pole disconnection switch with a contact
separation of at least 3mm at each pole should
be connected in fixed wiring.
Be sure to locate the power wiring and the
signal wiring well to avoid cross-disturbance.
Do not turn on the power until you have
checked carefully after wiring.
NOTE!
Remark per EMC Directive 89/336/EEC.
For to prevent flicker impressions during the
start of the compressor (technical process),
following installation conditions do apply.

5.1- CONNECT THE CABLE

Dissemble the bolts from the cover.
1 The power connection for the air conditioner
has to be done at the main power distribution.
The distribution has to be of a low impedance,
normally the required impedance reaches at a
32 A fusing point.
2 No other equipment has to be connected with
this power line.
3 For detailed installation acceptance please
refer to your power supplier, if restrictions do
apply for products like washing machines, air
conditioners or electrical ovens.
4 For power details of the air conditioner refer to
the rating plate of the product.
5 For any question contact your local dealer.
Connect the connective cables to the terminals
as identified with their respective mached
numbers on the terminal block of the unit.
Re-install the cover or the protection board.
14
Tabla de contenido
loading

Este manual también es adecuado para:

3-050 ak2-076 ak

Tabla de contenido