ECGF
The remote control button to be saved can be set in the following ways:
Operating modes
Motor
9. Wired control functions:
Operating modes
Motor
Operating modes
Lights
VIMAR group
Command
Description
configuration
The motor performs the step by step command, that is the UP-
Step by step
STOP-DOWN-STOP-UP... sequence will be run for each new
command received.
Upon receiving the command the control panel activates the up
Up/stop
relay for the set work time, with the up relay closed, on receiving
the command it deactivates the relay.
Upon receiving the command the control panel activates the
Down/stop
down relay for the set work time, with the down relay closed, on
receiving the command it deactivates the relay.
Upon receiving the command the control panel behaves as for the
step by step command without however implementing the stop
Step by step UP
command between up and down.
When you release the button or when the maximum work time
elapses the control panel deactivates the relay.
Upon receiving the command the control panel activates the up
relay.
Up UP
When you release the button or when the maximum work time
elapses the control panel deactivates the relay.
Upon receiving the command the control panel activates the
down relay.
Down UP
When you release the button or when the maximum work time
elapses the control panel deactivates the relay.
Upon receiving the command the control panel deactivates the
Stop
up and down relay
Upon receiving the command the control panel activates the up
Up
relay for a maximum time equal to the set work time
Upon receiving the command the control panel activates the up
Down
relay for a maximum time equal to the set work time
Note:
If no voltage is present, when the power supply comes back on the control panel will
keep the outputs deactivated until the user is given a command.
Input
Description
Input 1
Up/stop
Input 2
Down/stop
Input 1 +
Step by step
Input 2
(simultaneous)
Pulse duration
Description
The control panel presumes it is connected to a PUSH BUTTON.
< 1 s
Command executed only when the contact closes according to
the set output operating mode
The control panel presumes it is connected to a SWITCH.
> 1 s
Command executed both when the contact closes and when it
reopens according to the set output operating mode
EN
17