To set the boiler parameters, press (
activate, the "F01" appears on the display alternating with the value of the parameter shown.
Edit parameters
+/–
•
Press (
) to scroll through the parameters;
+/–
•
Press (
) to edit each parameter;
•
Press (
, to save the changes. "MEM" appears on the display;
)
i
•
Press (
, to exit without saving. "ESC" appears on the display.
)
Description of parameters
Type of boiler
F01
10 = sealed chamber 20 = atmospheric chamber
Gas used
00 = METHANE
F02
01 = LPG
02 = METHANE (WITH DIAPHRAGM)
F03
Hydraulic system
Setting programmable relay 1 (See SERVICE instructions)
00 = no associated function
01 = condominium alarm
F04
02 = ambient fan
03 = not used
04 = zone pump controlled by room thermostat (230V)
05 = not used
F05
Setting programmable relay 2 (DHW pump)
Maximum CH setpoint (°C)
F06
00 = 85°C - 01 = 45°C (function unavailable)
F07
DHW inlet priority configuration
F08
CH max. output (0-100%)
F09
DHW max. output (0-100%)
F10
Min. heating output (0-100%)
Delay prior to new ignition in CH mode
F11
(00-10 minutes) - 00=10 seconds
F12
Diagnostics (See SERVICE Instructions)
F13-F14-F15
Factory settings (no change)
Anti-legionella function
F16
00 = disabled
55...67 = enabled (setpoint °C)
CH pressure sensor selection
F17
00 = hydraulic pressure sensor
01 = hydraulic differential pressure sensor
F18
Manufacture information
22. ADJUSTMENT AND SAFETY DEVICES
The boiler has been designed in full compliance with European reference standards and in particular is fitted with the
following:
• Air pressure switch (model 24 BIC FF)
This device only allows the burner to ignite if the exhaust flue duct is in perfect working order.
In the event of one or more of the following faults:
•
flue terminal obstructed
•
venturi tubes obstructed
•
fan blocked
•
venturi tube connection - pressure switch tripped
the boiler remains on standby and error code E03 is displayed (see table in section 10).
INSTALLATION INSTRUCTIONS
21. PARAMETER SETTINGS
–
–
) and (
) together and hold down for at least 6 seconds. When the function is
76
Factory settings
24 BIC FF
24 BIC
10
20
02
15
04
03
00
00
100
100
00
03
--
00
00
00
00
71.06199.02 - EN