________________________________________________________________________ SMART CHARGER
6.0 -
FIRST CHARGE
•
Select FIRST CHARGE from the TYPE OF CHARGE menu and press ENTER to
start the charge.
The SELECT BATTERY Ah menu is displayed allowing selection of the battery capacity
(5 Ah to 160 Ah).
NOTA BENE:
For batteries over 160 Ah up to 200 Ah select the charge profile of 160 Ah.
•
Select the tested battery capacity and then press ENTER.
The selection of the type of battery is not required, the Standard type being
automatically selected since this is the battery that uses this function.
The following menu is displayed:
NOTA BENE:
In case of wrong connection of cables (polarity inversion) the battery charger informs
the operator by the message ATTENTION! BATTERY ANOMALY check battery and
connections.
The battery voltage minimum limits for recharge are the following:
Battery rated
voltage (V)
6
12
24
OPERATING INSTRUCTIONS
First charge
Standard
12 V
45 Ah
Battery voltage
minimum limit (V)
4
7,5
16
Pb
[START]
Battery voltage
maximum limit (V)
7,5
15
28
41