Parts Counting - Steinberg Systems SBS-BW Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
HOW TO SET IN
put the preset weight (e.g. 1000.0g), keep pressing [PACK] and the indicator shows
SET-AL; then the scale enter into choosing function mode. Press +/- for enter into
mode IN. Press [ZERO/TARE] to confirm and then enter into next setting; The indi-
cator shows AL-UP, then enter into LOWER limit set(e.g. input 995.0g). Press [ZERO/
TARE] to confirm and go for next step;
The indicator shows AL-DN, then enter into UPPER limit (e.g. input 1005.0g). Press
[ZERO/TARE] for confirmation and the indicator shows IN. It means the setting is
finished when the indicator keeps alarming.
Note: [IN] range between 1000.0g±5.0g is an example for customer's references.
HOW TO SET UPPER/LOWER LIMIT
[UNIT] and [HOLD] could be used to set upper & lower limit by inputting the num-
bers 0-9 into the setting. Press [UNIT] to increase and [HOLD] to decrease. Press
[ZERO/TARE] to confirm and quit setting.
SETTING OF ALARM
When indicator shows IN, it will alert the weight is between UPPER and LOWER
limit. When window shows OUT, it will alert the load exceeds the UPPER limit or
below LOWER limit. When window shows NO, it means it will not alarm without any
EN
load. Press [TARE/ZERO] to confirm the current selection.
HOW TO SET OUT
Put the preset weight (e.g. 1000.0g), keep pressing [PACK] and the indicator shows
SET-AL; then the scale enter into choosing function mode. Press +/- for enter into
mode OUT. Press [ZERO/TARE] to confirm and then enter into next setting; The
indicator shows AL-UP, then enter into UPPER limit set(e.g. input 1005.0g). Press
[ZERO/TARE] to confirm and go for next step. The display will show AL-DN and the
LOWER limit should be set (e.g. input 995.0 kg). Press [ZERO/TARE] to confirm and
then the display will show the 1000.0 kg. This means that settings are finished. Excee-
ding the lower limit (995.0 kg) is indicated by a beep and displaying (LLLLLL) on the
display. Exceeding the upper limit is indicated by a beep and displaying (HHHHHH) on
the display.

PARTS COUNTING

Setting the average weight of the sample
Turn on the scale and wait for weighing mode. Put the samples on the platform -
number of the samples must be 10/20/50/100/200/500/1000. Hold the [PCS] for a
while until the display will show the "P-XX", then press [UNIT] or [HOLD] in order
to set the number of samples – number must be the same as the amount of pieces on
12
the platform. Press [PCS] and the display will show the number of the pieces which
are currently on the platform.
Counting
Put the parts on the platform and the scale will show the actual amount of these
parts.
CALIBRATION
Simultaneously switch on the scale and press [ZERO/TARE], the display will show
the "------". Press the [PCS] + [UNIT] + [PCS] + [ZERO / TARE] – this will allow
for entering the calibration. Now enter the value of the weight which is going to be
placed on the platform by pressing the [PACK] / [PCS] for choosing the digit, press
the [HOLD] / [UNIT] for changing the value of the digits (for example: for 001000
the weight 1000kg can be placed on the platform), then press [ZERO/TARE], put the
entered weight on the platform, press [ZERO/TARE], the display will show the value
of the set weight. End of calibration.
13
EN
Tabla de contenido
loading

Este manual también es adecuado para:

Sbs-bw-3tSbs-bw-5tSbs-bw-1tSbs-bw-3t/1kgSbs-bw-5t/2kg

Tabla de contenido