VITO must be taken out of the fryer to confirm the error by pressing the push button (3)
The power indicator (red LED) (1) will continue to flash until VITO is cooled down.
Leave VITO 50 & VITO 80 plugged in. VITO is operational again after approx. 15 min.
It takes up to 2.5 hours if VITO is unplugged.
If VITO takes too long to cool down after a temperature based shutdown, the ambient temperature might
be too high or VITO was left in the fryer. VITO 80 will continue to beep every 40 seconds. Take VITO to a cool
place and plug it back in to allow the cooling fan to work.
Do NOT put VITO into a cold-storage room! Condensation can destroy the electrics.

9.4 Memory

VITO records the operating times and usage values. These values can be readout using the VITO Data Reader.
(see chapter 12 Accessories)

10. Care and servicing

10.1 Notes

Clean pump-filter unit (9) at every particle filter change
Clean VITO only if cooled down
Do NOT use abrasives
Do NOT use wire brushes or similar tools

10.2 Cleaning preparation

1. Make sure VITO is cooled down
2. Unfasten star handles (5) on both sides
3. Remove control unit (6) from pump-filter unit (9)
4. Open pump-filter unit (9)
5. Dispose particle filter
6. Manual or machine cleaning

10.3 Manual cleaning

1. Clean control unit (6) only with damp cloth!
2. DON'T put VITO under running water! This can destroy the electrics!
3. If strong dirt then deep clean (boil-out) / Clean the pump-filter unit (9) with soap sud.
4. Dry VITO with a towel.

10.4 Machine cleaning

1. Clean control unit (6) only with a
damp cloth! Do NOT put the electrical
unit (6) into a dishwasher!
This will destroy the electrics
2. Put pump-filter unit (9) and the drip pan (4)
into the dishwasher. Start the cleaning program.

11. Particle filter change

Change the particle filter only if necessary. The time of change is based on usage of VITO and the
degree of pollution of the frying oil.
Normal flow
Pay attention to the cleaning efficiency and the spill of oil coming out of the pump-filter unit. (9)
Change the particle filter only at a low filtration performance.
Low flow
Tabla de contenido