Berkel BH+25T Manual De Uso Y Manutención página 39

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

6.3
Emptying and cleaning BH+25T
-
Switch the on/off switch to position "0".
-
Raise the grille, unhook the three hinges "1" fig. 6.2.1, lift the front panel "5" fig.
6.2.1.
-
Remove all the mixture and rotor "2" fig. 6.2.1. Carefully clean the appliance, please
refer to paragraph. 7.6.
6.4
Emptying and cleaning
Switch the on/off switch to position "0". To empty and clean the mixing drum rotate it
by pulling knob "3" fig. 6.2.1.
Raise the cover and remove pins "4" that have to be removed before removing the ro-
tor. Pull the rotor upwards. Carefully clean the appliance, please refer to paragraph.
7.6.
6.6
Mounting rotor BH+25T
With the front panel "5" fig. 6.2.1 raised mount the rotor "2" fig. 6.2.1 onto its transmis-
sion shaft and by using one hand keep it raised above the mixing drum and close the
front panel "5" fig. 6.2.1.
Hook the three hinges "1" fig. 6.2.1 and close the grille "1" fig. 5.2.1.
6.7
Mounting rotors ME 80 - 180 BA
For mounting these rotors invert the procedure given in paragraph 6.5. and make sure
they are mounted in their correct position. To aid mounting both pins and rotors, these
have been stamped with numbers that must correspond when mounting the items.
Then close grille "1" fig. 5.2.1.
BH+50F - BH+80F - BH+180F