Weller WX 2 Manual De Uso página 30

Ocultar thumbs Ver también para WX 2:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
6-20
a
b
c
d
Fig. 3
Technical data of WX 2
Dimensions
Weight
Mains supply voltage
Power consumption
Safety class
Fuse
Temperature range
Temperature accuracy
Temperature stability
Equipotential bonding
Housing material
Operator panel material
Operator panel dimensions 74 x 38 mm
Resolution
Backlighting
Equipotential bonding
Four variants are possible by connecting the 3.5 mm jack socket
(14) differently:
− (a) Hard-grounded: supplied without plug.
− (b) Equipotential bonding: with plug, equaliser at centre contact.
− (c) Floating: with plug
− (d) Soft-grounded: with plug and soldered resistor. Grounded
through selected resistor.
USB port
The WX 2 control unit comes with a front-side USB port (10) for
installing firmware updates, configuration and monitoring. The USB
port (10) accepts any commercial USB memory stick.
L x W x H (mm): 170 x 151 x 130
L x W x H (inches): 6.69 x 5.94 x 5.12
approx. 3.2 kg
230 V, 50 Hz
200 W (240 W)
I, antistatic housing
Overcurrent trip T2 A
Adjustable from
50 °C – 550 °C (150 °F – 999 °F)
Controllable temperature range is
tool-dependent
± 9 °C (± 17 °F)
± 2 °C (± 4 °F)
Via 3.5 mm pawl socket on back of
device
Aluminium base
with antistatic black
(AMS 70002) coating; antistatic PA
plastic housing
Antistatic-coated real glass
255 x 127 (128) dots
4 LEDs
WX 2
Tabla de contenido
loading

Tabla de contenido